Green Heating Technology
3
SERVICE
M
anual
City Class F-FR
PCB Code
PCB Code is placed close to the control panel and it is visible leaving metal cover
PCB boiler combustion automatic check
• On every boiler electrical switching ON, PCB starts
• An automatic procedure for setting Boiler Combustion, which is equal to 3rd digit of PCB Code, on left corner of Control
Panel (i.e. 1 on picture for F model).
• If boiler feels air pressure switch changing its status, it sets 3rd digit to
1
• If boiler feels Flues Thermostat contact closed, it sets 3rd digit to
0
• If boiler does not receive any feedback in a one minute, it shows
E72
(Combustion Boiler error).
F FR
Digits
1st
2nd
3rd
4th
5th
Value
Aestethic
Gas Type
Power
Hydraulic
Not used
City Class F
City Class FR
City Class FR
City Class F
City Class FR
City Class F
Содержание CITY CLASS 20 F