Green Heating Technology
28
SERVICE
Manual
City Class F-FR
Technical data
F
U.M.
City Class 20 F
City Class 25 F
City Class 30 F
City Class 35 F
Gas type
G20
G30/G31
G20
G30/G31
G20
G30/G31
G20
G30/G31
Class
II
2H3+
II
2H3+
II
2H3+
II
2H3+
Type
B22 - C12 - C32 - C42 - C52 - C62 - C82
Working temperature
range (min÷max)
°C
0 ÷ +60
0 ÷ +60
0 ÷ +60
0 ÷ +60
Max heat input (Qn)
kW
21.0
20.5
25.7
25.5
30.0
29.0
30.0
29.0
Min heat input (Qr)
kW
9.5
10.0
10.0
10.2
12.0
13.0
12.0
13.0
Max heat output (Pn)
kW
19.5
19.0
24.0
23.8
28.2
27.3
28.2
27.3
Min heat output (Pr)
kW
8.1
8.5
8.5
8.6
10.2
11.1
10.2
11.1
NO
X
Class
3
3 / 3
3
3 / 3
3
3 / 3
3
3 / 3
CO at 0% O
2
(at Qn)
ppm
69.7
87.5 / 60.9
91.1
119.7 / 79.4
84.8
103.7 / 61.3
84.8
103.7 / 61.3
CO
2
at nominal input
%
5.5
6.4 / 6.3
7.2
8.1 / 7.9
7.5
8.4 / 8.0
7.5
8.4 / 8.0
Flue temperature (at Qn)
°C
118
110 / 112
119
111 / 113
122
121 / 120
122
121 / 120
Flue mass flow rate (at
Qn)
kg/h
53.74
53.62 / 54.22
51.93
53.21 / 53.82
58.58
57.11 / 59.11
58.58
57.11 / 59.11
Efficiency
Nominal efficiency (at Qn)
%
92.7
93.3
94.0
94.0
Efficiency at 30% Qn
%
90.5
91.0
91.5
91.5
Heating
Temperature selection
range (min÷max)
°C
35÷80
35÷80
35÷80
Expansion vessel
l
8
8
8
8
Exp.vessel pre-loading
pressure
bar
1
1
1
1
Loss of water pressure
switch
off / on pressure
bar
0.4 / 0.9
(±0.2)
0.4 / 0.9
(±0.2)
0.4 / 0.9
(±0.2)
0.4 / 0.9
(±0.2)
To allow the correct system filling, the pressure of the domestic water should be higher than the ON value of the pressure switch.
Max working pressure
bar
3
3
3
3
Max system temperature
°C
85
85
85
85
Anti-freezing function
temperature on / off
°C
5 / 30
5 / 30
5 / 30
5 / 30
Hot water
Flow rate at 25°C temp.
rise
l/min
11.2
10.9
13.7
13.6
16.2
15.6
18.6
18.6
Flow rate at 30°C temp.
rise
l/min
9.3
9.1
11.5
11.4
13.5
13.0
15.5
15.5
Min water flow
(for the DHW function activation)
l/min
2.8
2.8
2.8
2.8
Min supply pressure
(for the DHW function activation)
bar
0.2
0.2
0.2
0.2
Max supply pressure
bar
6
6
6
6
Temperature selection
range (min÷max)
°C
35÷55
35÷55
35÷55
35÷55
(follows)
Содержание CITY CLASS 20 F
Страница 1: ...CITY CLASS Manual SERVICE ENG 20 F 25 F 30 F 35 F 20 FR 25 FR 30 FR 35 FR Green Heating Technology ...
Страница 18: ...Green Heating Technology 18 SERVICE Manual City Class F FR DHW exchanger F FR ...