Green Heating Technology
16
SERVICE
Manual
City Class F-FR
Heating system filling and pressuring
Once all system connections have been carried out,
proceed with system filling. This operation should be
made with care, respecting the following steps:
f
Open the radiators venting devices;
f
Check that the plug of the automatic air vent, incor-
porated in the boiler circulator, is unscrewed: if not,
unscrew it and leave it unscrewed, even afterwards,
for normal operation;
f
If it’s required to fill the system with anti-freeze
solution, do this operation, then hermetically close
the connection or the valve used to put the solution
in, to allow the pressurization.
f
Gradually open the filling cock 2 ;
f
Check the correct functioning of automatic venting
devices, eventually installed;
f
Close the radiators venting devices as soon as water flows out of them;
f
Make sure, by reading the pressure gauge 1, that the pressure reaches the optimal value of 1.0 bar (max 1.5
bar);
f
Close the water filling cock 2 and bleed each radiator again;
f
Repeat the venting and pressurization operations until the air is completely purged from the system.