![Italsea 7CH4Q107 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/italsea/7ch4q107/7ch4q107_user-manual_2094841008.webp)
28/06/2013 7CH4Q107_E_4
7
Pin 10: ALARM
Connection for the diagnostic Blinking Led indicator (5Vdc-10mA) output : the
number of blinks means the alarm type (example 5 blinks means Alarm 5).
Pin 11: MODE 1
Default N.O. input to +V battery.
Pin 12: FORWARD SWITCH
N.O. input to +V battery.
Pin 13: BACKWARD SWITCH
N.O. input to +V battery.
Pin 14: COMMON HIGH
+V battery output for switches.
Pin 15: KEY IN
Key switch input (+V battery).
Pin 16: HOURMETER
Hour-meter output ( +V battery when running, 100mA max).
4v Molex connector
(Molex p/n.3901240, contacts p/n. 39000038)
Used for handheld programmer
M5 power screws
(M5)
+ B:
Positive DC power supply input,
- B:
Negative DC power supply input,
M1:
Positive Motor output
( in forward direction ),
M2:
Negative Motor output
( in forward direction )
F1: Power fuse 150A.
F2: Fuse 10A.
fig.5