MULTIMODE INPUT SETTINGS:
The input on pin 11 of the connector when closed activates a reduced speed
or current. This input activates:
- maximum motor speed;
- maximum motor current.
The input is always active.
Note: In the controller with handlhed programmer, the input on pin 11 activates
BACKWARD SAFETY SETTINGS (PUSH):
The function operate in the backward direction as a safety function for the operator. It is
realized by mean of a contact that activates the function when switched: the machine will
decelerate, will reverse the direction at a programmed speed for the programmed time,
then will stop.
The normal operation will be obtained resetting the input, the direction switches if present
and speed reference. The function is inhibit with the safety speed equal 0.
MULTIMODE SPEED
F24= ### %
DEFAULT: 50
MIN: 0
MAX: 100
MULTIMODE CURR.
F25= ## A
DEFAULT: 60
MIN: 0
MAX: 120
BW SAFETY TIME
F21= #.# s
DEFAULT: 0
MIN: 0
MAX: 100
BW SAFETY SPEED
F27= ### %
DEFAULT: 0
MIN: 0
MAX: 120