28/06/2013                                                 7CH4Q107_E_4                                 

                                    

 

 

12

 

 

HANDHELD PROGRAMMER PARAMETERS 

 
 

Parameter  Default 

Min 

Max 

Description 

 

 

 

 

 

F0 

Default parameters (F0=2) 

SWITCH-OFF AND ON THE KEY TO CONFIRM

 

F5 

3.0 

0.5 

5.0 

Acceleration ramp [s] 

F6 

1.5 

0.5 

5.0 

Reverse deceleration ramp [s] 

F7 

1.0 

0.5 

5.0 

Neutral deceleration ramp [s] 

F8 

120 

120 

Current limit [A] - Imax 

F9 

60 

100 

Backward speed reduction [%] 

F10 

s-en 

s-en 

w-w2 

Speed reference  
s-en

 =single ended potentiometer with FW,BW 

switches 

w-w1

=wig-wag potentiometer with EN switch 

w-w2

=wig-wag potentiometer without EN switch

 

F15 

2.0 

0.0 

10.0 

Brake delay [s] 

 

F16 

20 

Min speed ( % of max speed) 

F17 

25 

40 

Motor’s rated current – In 

F18 

60 

60 

Motor’s overload time [s] – t 

F19 

200 

50 

500 

Dead band of the speed reference [V]   

F21 

100 

Backward  safety time 

 

F22 

100 

100 

Forward maximum speed [%] 

F24 

50 

100 

Multimode input = speed reduction  [% ]  

F25 

60 

120 

Multimode input = current limit [A]   

F26 

0.0 

0.0 

10.0 

RxI [100=10% at 120A (5% 60A)] 

F27 

100 

Backward safety speed [% of max speed] 

F28 

V24 

V24 

V36 

Battery voltage  

AFTER CHANGE SWITCH-OFF AND ON THE KEY

 

--- 

no 

no 

--- 

Enable potentiometer calibration 

--- 

ITAL. 

ITAL. 

ENGL.  Selected language 

SWITCH-OFF AND ON THE KEY TO CONFIRM

 

F30 

--- 

--- 

--- 

Access key for engeneering parameters  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 7CH4Q107

Страница 1: ...7CH4Q107_E_4 DATE 28 06 2013 REV 4 0 7CH4Q107 MICROPROCESSOR FOUR QUADRANT CONTROLLER FOR PM DC MOTORS EXTERNAL PROGRAMMER USER S GUIDE...

Страница 2: ...nnector Page 7 power screws Page 7 CONTROLLER SETTING 7PROGLCD HANDHELD PROGRAMMER Page 8 TESTER MODE Page 9 ALARMS Page 10 11 PARAMETERS PARAMETRS Page 12 RESET TO DEFAULT Page 13 GENERAL SETTING Pag...

Страница 3: ...he current is very low so the efficiency of the system is very high The chopper is designed in accordance with the most important EC standards FEATURES POWER SUPPLY BATTERY 24 36 V RATED CURRENT 30A M...

Страница 4: ...28 06 2013 7CH4Q107_E_4 3 MECHANICAL DRAWING fig 1...

Страница 5: ...l abuse water and dirty Fix it with all the screws on a metal surface aluminum if possible to reduce the heath and so for longer period of work If during the standard operations the thermal protection...

Страница 6: ...28 06 2013 7CH4Q107_E_4 5 COMPLETE WIRING DIAGRAM...

Страница 7: ...6 DISABLE Default N C input contact When the contact is open the controller will decelerate Neutral Ramp will check if the motor voltage is near zero motor stopped and after the electro brake delay wi...

Страница 8: ...WITCH N O input to V battery Pin 14 COMMON HIGH V battery output for switches Pin 15 KEY IN Key switch input V battery Pin 16 HOURMETER Hour meter output V battery when running 100mA max 4v Molex conn...

Страница 9: ...voltage speed reference input internal aluminum heat sink temperature battery voltage hour meter and software release To start the programming function push the button MODE Will appear the first para...

Страница 10: ...voltage measure measure unit Volts REFERENCE INPUT Vref Volts Speed reference voltage measure unit Volts potentiometer or voltage 0 5V speed reference HEATSINK TEMP T C F Internal heat sink temperatur...

Страница 11: ...he speed reference to zero and open the BW switch ALARM A3 POT FAULT Potentiometer fault Check the potentiometer s wires ALARM A4 POTI OUT OF ZERO Potentiometer out of neutral position at power on Mov...

Страница 12: ...ery voltage upper than 45V check the battery ALARM A10 OVERVOLTAGE Overload protection Check the motor working current and parameters rated current and overload time ALARM A11 OVERLOAD CURRENT Disable...

Страница 13: ...wag potentiometer without EN switch F15 2 0 0 0 10 0 Brake delay s F16 0 0 20 Min speed of max speed F17 25 0 40 Motor s rated current In F18 60 0 60 Motor s overload time s t F19 200 50 500 Dead band...

Страница 14: ...from stop position to max settled speed REVERSE RAMP Reverse direction deceleration ramp time in seconds from the current direction to reverse direction NAUTRAL RAMP Deceleration ramp time in seconds...

Страница 15: ...n max speed MINIMUN SPEED Minimum speed value in percent of battery voltage BATTERY VOLTAGE Battery supply voltage set the value between options 24V or 36V RxI COMPENSATION further improve FW MAX SPEE...

Страница 16: ...D REFERENCE page and confirm it by MODE button Single ended potentiometer potentiometer with two direction switches Wigwag1 potentiometer potentiometer with middle stop position and enable switches Wi...

Страница 17: ...p 2 POTI COURSE no Choose tar to set poti course option and confirm it by UP button Step 3 POTI CALIBR Vzero V Set the potentiometer or throttle at STOP NEUTRAL position and confirm it by MODE button...

Страница 18: ...n and confirm it by MODE button Step 4 POTI COURSE no Choose tar to set poti course option and confirm it by UP button Step 5 POTI CALIBR Vzero V Set the potentiometer or throttle at STOP NEUTRAL posi...

Страница 19: ...lectro brake coil when the motor is running the coil is powered off with delay when the speed reference and direction switches are in stop position Brake ON Brake OFF Motor ON Motor OFF Time Time BRAK...

Страница 20: ...on as a safety function for the operator It is realized by mean of a contact that activates the function when switched the machine will decelerate will reverse the direction at a programmed speed for...

Страница 21: ...urrent as follow Imax2 In2 t K In Imax t rated motor current max motor current overload time at the max current Once calculated the K is possible to calculate the ammeter time protection at your worki...

Страница 22: ...NGENEERING PROTECTED PARAMETERS IGSL DEFAULT MIN MAX 0 0 99 PGSL DEFAULT MIN MAX 0 0 99 IGCL DEFAULT MIN MAX 0 0 99 PGCL DEFAULT MIN MAX 0 0 99 LPOT DEFAULT MIN MAX 0 0 99 CPOT DEFAULT MIN MAX 0 0 99...

Отзывы: