![Italsea 7CH4Q107 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/italsea/7ch4q107/7ch4q107_user-manual_2094841013.webp)
28/06/2013 7CH4Q107_E_4
12
HANDHELD PROGRAMMER PARAMETERS
Parameter Default
Min
Max
Description
F0
0
0
2
Default parameters (F0=2)
SWITCH-OFF AND ON THE KEY TO CONFIRM
F5
3.0
0.5
5.0
Acceleration ramp [s]
F6
1.5
0.5
5.0
Reverse deceleration ramp [s]
F7
1.0
0.5
5.0
Neutral deceleration ramp [s]
F8
120
0
120
Current limit [A] - Imax
F9
60
0
100
Backward speed reduction [%]
F10
s-en
s-en
w-w2
Speed reference
s-en
=single ended potentiometer with FW,BW
switches
w-w1
=wig-wag potentiometer with EN switch
w-w2
=wig-wag potentiometer without EN switch
F15
2.0
0.0
10.0
Brake delay [s]
F16
0
0
20
Min speed ( % of max speed)
F17
25
0
40
Motor’s rated current – In
F18
60
0
60
Motor’s overload time [s] – t
F19
200
50
500
Dead band of the speed reference [V]
F21
0
0
100
Backward safety time
F22
100
0
100
Forward maximum speed [%]
F24
50
0
100
Multimode input = speed reduction [% ]
F25
60
0
120
Multimode input = current limit [A]
F26
0.0
0.0
10.0
RxI [100=10% at 120A (5% 60A)]
F27
0
0
100
Backward safety speed [% of max speed]
F28
V24
V24
V36
Battery voltage
AFTER CHANGE SWITCH-OFF AND ON THE KEY
---
no
no
---
Enable potentiometer calibration
---
ITAL.
ITAL.
ENGL. Selected language
SWITCH-OFF AND ON THE KEY TO CONFIRM
F30
---
---
---
Access key for engeneering parameters