Use and maintenance manual
10
Model EGB/2
Model EGB
Страница 1: ...PDS 4402 013 05 10 2005 USE AND MAINTENANCE MANUAL ECO GAS A B Category II2H3 Construction type A B11 0705...
Страница 2: ...ODUCTION This manual contains the necessary instructions for use and the safety rules to be applied for the correct operation of the appliance This manual must be given to the people in charge of usin...
Страница 3: ...ly and installation site 2 2 Gas connection 2 3 Electrical connection CHAP 3 COMMISSIONING for the installer 3 1 Checking the nominal thermal capacity 3 2 Checking the gas supply pressure 3 3 Conversi...
Страница 4: ...or assessing compliance with the essential requisites set out by gas Directive 2009 142 EEC The oven or the quality of the production system are subject to periodic monitoring through inspection check...
Страница 5: ...ommissioning This instruction manual must be keep with the oven for future reference If the oven is sold or transferred make sure that the manual always accompanies it so that the new user can be info...
Страница 6: ...face Avoid all direct contact with these surfaces 1 2 Technical data plate and supplementary plate The technical data plate Fig 1 is located at the rear of the oven and contains the voltage rating and...
Страница 7: ...aust fumes flue 120 mm minimum length 500 mm Appliance category II2H3 Type of construction A B11 Electrical power supply 220 230 V 50 Hz Power cable Type H05RN F 3x1 5 mm2 Gas supply pressure Liquid b...
Страница 8: ...Use and maintenance manual 8 Model EGA Model EGA 2...
Страница 9: ...120 mm minimum length 500 mm Appliance category II2H3 Type of construction B11 Electrical power supply 220 230 V 50 Hz Power cable Type H05RN F 3x1 5 mm2 Gas supply pressure Liquid butane propane gas...
Страница 10: ...Use and maintenance manual 10 Model EGB 2 Model EGB...
Страница 11: ...stallation premises The ovens are fitted with a windproof device incorporated into the exhaust circuit in the event of a flue obstruction or abnormal draught Connect a straight section of pipe no less...
Страница 12: ...less than 500 mm in length and with 120 mm diameter for optimal draught The oven should be positioned fully horizontally on the stand or on a stable structure at a distance of no less than 100 mm from...
Страница 13: ...Use and maintenance manual 13 M i n 500mm R M i n 5 0 0 m m M i n 5 0 0 m m M i n 500mm R V C Fig 4a Fig 4b Key C Interlocked extractor hood R Stop cock upstream of the oven V Hood cut off valve...
Страница 14: ...in compliance with the regulations in force Before performing the electrical connection make sure that the voltage and frequency shown on the technical data plate are the same as those of the power su...
Страница 15: ...the required range with a tolerance of 5 If any deviations are found check that injectors of the correct size have been fitted 3 2 Checking the gas supply pressure Before putting the oven into service...
Страница 16: ...type of gas by following the instructions in table 3 Table 3 Type of gas Outgoing gas pressure mbar Procedure to be followed Methane gas G20 9 Adjust the screw T until the value stated opposite is rea...
Страница 17: ...ical power supply Check that the diameter of the injector is stamped on it in 1 100 of a mm Perform the following operations in sequence To access the devices to be adjusted and replaced remove the ov...
Страница 18: ...s inlet and outlet connections on the valve and remove the gas pipes Disconnect the electrical connections to the solenoid valve Undo the two screws fastening the solenoid valve to the base support an...
Страница 19: ...ected The safety thermostat has tripped or is faulty B The burner does not ignite shuts down continuously or switches off Possible causes The ignition plug is not secured properly is connected incorre...
Страница 20: ...order for this reason it is recommended to take out a maintenance contract 4 1 Start up Before switching the oven on for the first time clean it thoroughly to remove the film of grease Check that the...
Страница 21: ...e red thermostat indicator H to zero 0 Disable the main switch F After use close the gas shut off cock downstream of the oven and disconnect it from the power supply Running in Set the thermometer to...
Страница 22: ...e reset manually and must be performed by a specialised technician Access this component by removing the right side panel of the oven Flame control The flame detection electrode is connected to the PC...
Страница 23: ...daily basis with warm soapy water or suitable detergents rinsing thoroughly and drying well Do not use detergents that contain chlorine bleach muriatic acid etc and never clean the steel parts with sc...
Страница 24: ...nsformer for chamber light LC Cooking chamber light SB Shutdown warning light EVG Gas inlet solenoid valve RESET Flame control shutdown reset E RIV Flame detection electrode E ACC Flame ignition elect...
Страница 25: ...____________________________________ ________________________________________________________________________________ ________________________________________________________________________________ _...