background image

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This document and all documents accompanying it are copyrighted by iSYSTEM AG and all 
rights are reserved. Duplication of these documents is allowed for personal use. In all other 
cases, written consent from iSYSTEM is required. 
 
Copyright 

©

  iSYSTEM AG.  

All rights reserved.  
All trademarks are property of their respective owners. 
 
iSYSTEM is an ISO 9001 certified company. 
 

www.isystem.com 

 

Содержание IC57164

Страница 1: ...Infineon AGBT Active Probe V1 7 User Manual ...

Страница 2: ...ghts are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required Copyright iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Страница 3: ...n 8 Device overview 8 Device description 8 Target connector 9 10 pin 1 27 mm DAP Adapter 9 Active Probe and the iC5700 Connecting Guidelines 11 Setting Debug Interface Voltage Levels 11 Further Active Probe Settings 12 Lane link speed 14 Accessories 15 Infineon AGBT Active Probe Accessories 15 ...

Страница 4: ...winIDEA can also visualize the timing and code coverage of the application via the trace interface as well as combine data captured by our IOM Accessories Various third parties also provide software tools to perform advanced worst time execution analysis based upon the data winIDEA can export When a Real Time Operating System RTOS is in use the state of the RTOS and its tasks can also be visualize...

Страница 5: ...s is to avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not to...

Страница 6: ...s InfineonAGBTActiveProbe 1 m FNET Cable User manual Ordering code IC57164 Ordering code BB FNET 100 The Infineon AGBT Active Probe kit ordering code IC57164 62 can be delivered with longer cable i e 62 cm in length InfineonAGBTActiveProbe 1 m FNET Cable User manual Ordering code IC57164 62 Ordering code BB FNET 100 ...

Страница 7: ...ox iSYSTEM proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 3W dependent on operation mode Number of supported AGBT lanes Up to 4 Maximum AGBT bitrate 5Gbps AGBT clock source options Active Probe PROTECTION Debug signals 33Ω series termination protection resistors ESD protection devices DAP1 3 10kΩ pull down DAP_RESET 1kΩ pull up 33Ω series termination pr...

Страница 8: ...1 12 TRST DAPEN Output O I AGBT TX2_P TX2 13 14 CLK AGBT clock O I AGBT TX2_N TX2 15 16 CLK AGBT clock O Ground GND 17 18 TGO AGBT trigger out I AGBT TX3_P TX3 19 20 NC Not Connected I AGBT TX3_N TX3 21 22 RESET Target Reset Pin IO Current TriCore devices feature only one AGBT lane while the Active Probe hardware is ready for future devices which could have more AGBT lanes Signal direction definit...

Страница 9: ...any other accessory Target connector The target should feature a matching part for example Samtec part number ASP 137969 01 Samtec Series ERF8 Rugged High Speed Socket Infineon TriCore target can also feature a standard 10 pin 1 27mm DAP target debug connector exposing only the debug interface without the AGBT interface The Active Probe can be used to connect to such targets through a small adapte...

Страница 10: ...10 If the 10 pin 1 27 mm pitch ribbon cable gets damaged it can be ordered as a spare part under the ordering code IA10PIN10PIN127 Detached 10 pin 1 27mm pitch ribbon cable ...

Страница 11: ... Connect the iC5700 to the PC via the supplied Ethernet or the USB 3 0 cable Connect the Active Probe to the iC5700 FNET Port through the supplied FNET Cable If a cable longer than 1 0m is required for example when debugging an ECU in a vehicle or a confined space optional 3m and 5m FNET cables are available from iSYSTEM Although it looks similar to the HDMI interface the FNET Port is not compatib...

Страница 12: ...atively JTAG debug interface support is also available through a dedicated JTAG cable adapter e g IC50160 or the Infineon DAP Active Probe supporting the DAP and DAPE debug interface or the Infineon AGBT Active Probe In order to switch from the default DTM interface use to the Active Probe use open Hardware menu Options FNet tab 1 In Currently connected FNodes section click Refresh and select the ...

Страница 13: ...d select the displayed AP Infineon AGBT If you have several Active Probes connected to your BlueBox select the desired Active Probe from the drop down menu If you have only one Active Probe connected you can leave the Active Probe selection box empty and winIDEA will automatically connect to an available Active Probe ...

Страница 14: ... interface Hence once the Analyzer trace operation e g trace or profiler or coverage is confirmed with the default setting higher Aurora link speeds should be tested and the highest operational speed then selected for usage This way the Active Probe will be configured for maximum possible Analyzer session time Different speeds 1 25Gbps 2 5Gbps are available Other more general of Infineon s AURIX m...

Страница 15: ...41 Analog Digital Input Output Add On Module IC57125 1 ARM HSSTP II Active Probe IC57163 Infineon DAP DAPE Active Probe IC57164 Infineon AGBT Active Probe IC57150 MPC5x SPC5x Aurora Active Probe Infineon AGBT Active Probe Accessories Ordering Code Description IASAM22TRICOREPIN10 10 pin 1 27 mm DAP Adapter BB FNET 100 1 0m FNet Cable BB FNET 300 3 0m FNet Cable BB FNET 500 5 0m FNet Cable Please re...

Страница 16: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...