background image

4

Seebacher GmbH 

www.seebacher.de 

Phone: +49 (0) 80 41 / 77 77 6

Marktstrasse 57, 83646 Bad Tölz 

[email protected] 

Fax: +49 (0) 80 41 / 77 77 2

6. Maintenance / Care / Disposal

The product is maintenance-free. It is sufficient from time to time to 
remove any dust deposits. This may only be done in a power-free 
state.

Disposal (European Union)
Do not dispose of product in household waste! Products with this 
symbol

7. Storage

The product must be stored in a dry place, protected from dirt and 
mechanical stress. After damp or dirty storage, the product may only 
be operated after a condition check by an authorised electrician. 

8. Assembly

(Only by certified electrician!)
Mount the product only when it is in a power-free state!
Switch off the power supply, check that there is no voltage, secure 
against being switched on again!

Only use suitable equipment that meets the electrical requirements 
of the device!
Check that there are no loose parts in the product. If this is the case 
and the presence of such parts is not explicitly described, do not 
install or commission the product. 
Only use suitable cables and fixing screws. 

Assembly site
• Depending on the design, the product is intended for surface or 

flush mounting or for installation in luminaires or profiles.

Assembly steps
(Read completely before assembly!) 
• Mount the device in a way that the light sensor looks into the area 

to be measured. The sensor works with the reflection measure-
ment method, so direct light irradiation by the luminaire must be 
avoided.

• Make the electrical connections according to the wiring diagram. 
• Only after a complete connection and a visual test by a qualified 

electrician, the system may be put under voltage.

Seebacher GmbH

Marktstrasse 57
83646 Bad Tölz
GERMANY

Phone: +49 (0) 80 41 / 77 77 6 
Fax: +49 (0) 80 41 / 77 77 2

www.seebacher.de
[email protected]

5. Service address

4. Declaration of Conformity

The valid declaration of conformity for the module can be requested 
from us free of charge by stating type and article no. as follows:
By phone: 

+49(0)8041/77776

By fax: 

+49(0)8041/77772

By mail: 

[email protected]

3. Warranty

We provide warranty within the framework of the statutory provisi-
ons. These are limited to the intended use of the module and refer 
to the repair or replacement of the ISYGLT module. Please send the 
device with an attached error description to our company address 
given below. 

must be disposed of according to the EU directive WEEE 2012/19/
EU on waste electrical and electronic equipment at the local collec-
tion points for waste electrical and electronic equipment!

Содержание LS-06-PIR-01-WH

Страница 1: ...cher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 LS 06 PIR xx WH xx Article no 8008507x xx Light and PIR Motion Sensor passive infrared Technica...

Страница 2: ...m 1 Notes on documentation These instructions are intended for qualified personnel who are familiar with the assembly installation and operation of the ISYGLT system It is essential that you read thes...

Страница 3: ...ces SEEBACHER accepts no liability for printing errors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of...

Страница 4: ...face or flush mounting or for installation in luminaires or profiles Assembly steps Read completely before assembly Mount the device in a way that the light sensor looks into the area to be measured T...

Страница 5: ...EKMC2607111K 46 4 x 20 4 x 14 15 8 mm 12g LS 06 PIR 01 WH APG 80085071 61 Surface mounted housing GIRA System 55 Low Profile Type 110 x110 3m 5m Sensor EKMC2607111K 80 x 80 x 59mm 145g LS 06 PIR 01 W...

Страница 6: ...suring range illuminance 0 to 4500 lx depending on mounting Connection Mini plug Molex 51021 0400 4 pole cable to RJ10 incl terminal adapter Delivery scope Sensor 250mm connection cable RJ10 adapter f...

Страница 7: ...must be created as a module Additionally a virtual module ISYGLT_ADR is required To set the BUS address the desired address must be entered in the register Parameter Now the sensor to be addressed mus...

Страница 8: ...e Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 10 4 View LS 06 PIR 02 WH APG LS 06 PIR 01 WH APG LS 06 PIR 02 WH UP LS 06 PIR 01 WH UP LS 06 PIR 01...

Страница 9: ...hone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 11 Detection ranges PIR sensor types LS 06 PIR 01 WH xx Low ProfileType Detection area 110 x 110 Typical...

Страница 10: ...80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 LS 06 PIR 02 WH xx Standard Slight Motion Detection area Slight Motion 44 x 44 Detection area Standard Motion 91 x...

Страница 11: ...0 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 Misprints and technical changes reserved 12 Wiring diagram LS 06 PIR xx xx Art no 8008507x Light PIR motion sensor...

Отзывы: