Depending on the design, the module is intended for surface or 
flush mounting or for installation in luminaires or profiles. The 
position is arbitrary, but care must be taken to ensure a useful 
detection direction of the light. Extreme environmental conditions 
impair the function of the product.

• 

Protect module from shocks

• 

Use module indoors only

• 

Protect module from humidity

In addition to these safety instructions, you must also observe 
the special safety instructions listed in the individual chapters for 
the individual acts.

2.4. Qualification of staff

Assembly, commissioning, operation, maintenance, decommis-
sioning and disposal may only be carried out by qualified staff. 
Work on electrical parts may only be carried out by a trained 
electrician in accordance with the applicable regulations and 
directives. Other activities in connection with the ISYGLT module, 
such as assembly and installation of system components with 
tested standard plug connections, as well as operation and con-
figuration of the ISYGLT module may only be carried out by trai-
ned staff.

2.5. Changes to the product 

Unauthorized modifications to the ISYGLT module which are not 
described in this or the other applicable instructions can lead to 
malfunctions and are prohibited for safety reasons.

2.6. Use of spare parts and additional equipment

The module may be damaged if unsuitable spare parts and addi-
tional equipment are used. Only use original spare parts and 
additional equipment from the manufacturer.

2.7. Liability notes

SEEBACHER accepts no liability or warranty whatsoever for 
damage and consequential damage caused by non-compliance 
with the technical regulations, instructions and recommendati-
ons. SEEBACHER shall not be liable for any costs or damage 
incurred by the user or third parties as a result of the use of this 
equipment, in particular improper use of the equipment, misuse 
or malfunction of the connection, malfunction of the equipment 
or connected devices. 

SEEBACHER accepts no liability for printing errors.

2. Safety instructions

Observe the following general safety instructions when installing 
and commissioning the device:

Assembly and installation of the ISYGLT module may only be carried 
out by a qualified electrician. Other activities in connection with the 
ISYGLT module, such as assembly and installation of system com-
ponents with tested standard plug connections, as well as operation 
and configuration of the ISYGLT module may only be carried out by 
trained staff.

Observe the electrical installation regulations of the country in which 
the device is installed and operated as well as its national accident 
prevention regulations. In addition, observe internal company regu-
lations (work, operating and safety regulations).

Before working on the ISYGLT module system, it must be 
disconnected from the power supply and secured against 
being switched on again. After completion of the assembly, 
installation and maintenance work, an electrical check must 
be carried out! Check all protective conductor connections 
and the voltages at all connection plugs as well as at each 
individual module slot.

2.1. Intended usage 

The module is exclusively suitable for regulation (control) in con-
junction with ISYGLT system components. Any other use is not 
intended. The limit values stated in the technical data must not be 
exceeded under any circumstances. This applies in particular to 
the permissible ambient temperature range and the permissible 
IP protection type. For applications with a higher required IP pro-
tection type, the ISYGLT module must be installed in a housing 
or a cabinet with a higher IP protection type.

2.2. Predictable mishandling

The module must not be used in the following cases in particular: 

 explosive area 

When operating in explosive areas, sparking can lead to defla-
gration, fire or explosions.

2.3. Safe handling

This module corresponds to the state of the art and the recog-
nised safety regulations. Each device is tested for function and 
safety before delivery.

Only operate this module in perfect condition in accordance with 
the operating instructions, the applicable regulations and directi-
ves of the country in which the device is installed and operated, 
and the applicable safety and accident prevention regulations.

Содержание LS-06-PIR-01-WH

Страница 1: ...cher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 LS 06 PIR xx WH xx Article no 8008507x xx Light and PIR Motion Sensor passive infrared Technica...

Страница 2: ...m 1 Notes on documentation These instructions are intended for qualified personnel who are familiar with the assembly installation and operation of the ISYGLT system It is essential that you read thes...

Страница 3: ...ces SEEBACHER accepts no liability for printing errors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of...

Страница 4: ...face or flush mounting or for installation in luminaires or profiles Assembly steps Read completely before assembly Mount the device in a way that the light sensor looks into the area to be measured T...

Страница 5: ...EKMC2607111K 46 4 x 20 4 x 14 15 8 mm 12g LS 06 PIR 01 WH APG 80085071 61 Surface mounted housing GIRA System 55 Low Profile Type 110 x110 3m 5m Sensor EKMC2607111K 80 x 80 x 59mm 145g LS 06 PIR 01 W...

Страница 6: ...suring range illuminance 0 to 4500 lx depending on mounting Connection Mini plug Molex 51021 0400 4 pole cable to RJ10 incl terminal adapter Delivery scope Sensor 250mm connection cable RJ10 adapter f...

Страница 7: ...must be created as a module Additionally a virtual module ISYGLT_ADR is required To set the BUS address the desired address must be entered in the register Parameter Now the sensor to be addressed mus...

Страница 8: ...e Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 10 4 View LS 06 PIR 02 WH APG LS 06 PIR 01 WH APG LS 06 PIR 02 WH UP LS 06 PIR 01 WH UP LS 06 PIR 01...

Страница 9: ...hone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 11 Detection ranges PIR sensor types LS 06 PIR 01 WH xx Low ProfileType Detection area 110 x 110 Typical...

Страница 10: ...80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 LS 06 PIR 02 WH xx Standard Slight Motion Detection area Slight Motion 44 x 44 Detection area Standard Motion 91 x...

Страница 11: ...0 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 Misprints and technical changes reserved 12 Wiring diagram LS 06 PIR xx xx Art no 8008507x Light PIR motion sensor...

Отзывы: