88
(5) Starter
and
Alternator
Servicing
Do the starter and the alternator servicing
every 1000
operating hours
on the following items.
•
Starter
commutator
cleaning.
•
Alternator slip ring cleaning.
•
Carbon brushes and the brush contact check.
(6)
Radiator Pressurization Valve Check
A pressurization valve is incorporated in the radiator cap assembly.
Check the valve actuating pressure with a radiator compression tester.
For the pressurization valve actuating pressure and the check interval,
follow the equipment manufacturer’s standards.
Содержание AU-4LE1T
Страница 25: ...20 Engine model Serial number 4LE1 000000 IMLE0092...
Страница 63: ...58 4LE1T Oil drain plug Oil filler cap Oil filler cap Oil level gauge IMLE0094...
Страница 64: ...59 4LE1NA Oil drain plug Oil filler cap Oil filler cap Oil level gauge IMLE0095...
Страница 79: ...74 C O OPEN Lever Element Cup Drain plug Ring nut Air bleeder plug CLOSE IMLE0059...