background image

L.83.0072 - Release 8.0.1 CH 2013
ista International GmbH - Grugaplatz 2 - 45131 Essen
http//www.ista.com

Nur für den internen Gebrauch—For internal use only—Uniquement pour utilisation interne

Device Manual
Chapter 4.1-R optosonic u 3 radio net

Содержание optosonic u 3 radio net

Страница 1: ...0 1 CH 2013 ista International GmbH Grugaplatz 2 45131 Essen http www ista com Nur f r den internen Gebrauch For internal use only Uniquement pour utilisation interne Device Manual Chapter 4 1 R opto...

Страница 2: ...3 Technical data 6 1 4 Main and connection dimensions 7 2 Item numbers 8 3 Installation 9 3 1 Screwed installation 9 3 2 Installation with cable ties 9 3 2 1 With mounting plate 9 3 2 2 Without mounti...

Страница 3: ...description The radio module optosonic u 3 radio net serves in in tegrating the heat meter ultego III into the radio system symphonic sensor net For this the opto head of the optosonic u 3 radio net i...

Страница 4: ...o rm on at Info ultego Klasse 3 EN 1434 Umgeb ungsklasse M1 E1 1 2 s p i 0 6 0 01 2 m h m h m h Fabr Nr 65 42 7 30 7 F hler Pt 50 0 3 80 K 15 105 C PN 16 DN 15 Einbau im R cklauf 2W R6 05 1 7B B2 5 0A...

Страница 5: ...or each error combination Example Error status 17 16 1 16 Battery weak non critical 1 Dismantling detection Consequence Exchange device due to the error status 1 as partial error Art N 19449 S N XXX X...

Страница 6: ...MHz Duration of transmission telegram 10 msec transmission Transmission rate 90 kbaud bit sec Transmission method bidirectional Data integrity encrypted transfer Weight 0 110 kg Material ABS Casing co...

Страница 7: ...y values heat cold of the previous day Volume of the last day Energy values heat cold of the last two target dates Volume of the last two target dates Date of the last two target dates 14 month end va...

Страница 8: ...2 4 Y optosonic u 3 radio net Nur f r den internen Gebrauch For internal use only Uniquement pour utilisation interne Devices Accessories 2 Item numbers 19449 optosonic u 3 radio net 19452 optosonic p...

Страница 9: ...g plate for determining the hole distance 3 Insert dowels 4 Attach the mounting plate to the wall 5 Align the mounting plate vertically using spirit level 6 Tighten screws firmly Continue with Final s...

Страница 10: ...3 3 Final steps 1 Position module on mounting plate if installing with mounting plate 2 Clean the contact surface on the ultego III 3 Pull off the protective foil from the rear of the opto head 4 Glu...

Страница 11: ...ith the PDA 6 The device will go into the measuring mode after parame terisation or 4 minutes Continue with step 10 after the parameterisation Continue with step 7 after 4 minutes without parameteri s...

Страница 12: ...lisation interne 5 1 Replace optosonic u 5 1 1 Preparatory steps 1 Disconnect the opto head from ultego III 5 1 2 For installation on mounting plate 1 Remove old optosonic u 3 radio net from the mount...

Страница 13: ...opto head 4 Remove the protective foil from one side of the new adhesive pad 5 Glue the new adhesive pad on to the opto head 6 Pull off the protective foil from the rear of the opto head 7 Glue opto...

Страница 14: ...15 2 4 Y optosonic u 3 radio net Nur f r den internen Gebrauch For internal use only Uniquement pour utilisation interne 6 1 Radio reading AMM 1 Readout via symphonic sensor net 6 2 Radio reading Wal...

Страница 15: ...evice Manual 2 4 Y optosonic u 3 radio net 15 15 Nur f r den internen Gebrauch For internal use only Uniquement pour utilisation interne 1 Do not dispose of the old device in the household waste 2 Sen...

Отзывы: