L.83.0072 - Release 8.0.1 CH 2013
ista International GmbH - Grugaplatz 2 - 45131 Essen
http://www.ista.com
Device Manual
6/15
2.4-Y optosonic u 3 radio net
Nur
für
den
in
ter
n
en
Geb
rauc
h
— For int
e
rn
al us
e on
ly
— Unique
ment
pou
r ut
ilisa
tion int
e
rn
e
1.3
Technical data
Functional principle
Optical read-out of connected counters
Interfaces
▪
Output:
Radio interface for the ista radio system symphonic sensor net.
▪
Input:
Opto head (protected against reversed polarity), cable length 0.5 m.
Radio interface
▪
Compatible with symphonic sensor net
▪
Transmission power: < 10 mW
▪
Radio frequency: 868 MHz
▪
Duration of transmission telegram: < 10 msec/transmission
▪
Transmission rate: ~ 90 kbaud (bit/sec)
▪
Transmission method: bidirectional
▪
Data integrity: encrypted transfer
Weight
0.110 kg
Material
ABS
Casing colour
RAL 9002
CE label
1999/5/EC
Storage
Temperature:
▪
1st year: -25 °C to +70 °C
▪
then 0 °C to +70 °C
To be stored in a dry place
Ambient temperature
0 °C - 70 °C
Relative humidity
5 % - 95 %
Protection class
IP54 acc. to EN 60529
i.e.:
▪
Protection against foreign objects: Protects against damaging amount of dust.
▪
Protects against contact: complete protection against contact.
▪
Protection against water: Protection against splash water on all sides.
Power supply
2 x 3 V lithium battery
Life cycle
10 years + 1 year r 1 year storage
Parameterisation data
▪
Radio network number
▪
Reference date