IST GP-3000 DATA+ Скачать руководство пользователя страница 2

______________________________     

IST PROLINE

 

 

 

 

CONTENT 

 

I. General Information 
  1.1. Hardware Specification 
 
II. Operational modes 
   2.1. General 
      2.2. Operational Modes Flow Chart & Functions 
       2.2.1. Time mode 

             

2.2.2. Dive set mode (Gage dive set mode) 

             

2.2.3. Dive plan mode 

             

2.2.4. Dive Log Mode

 

             

2.2.5. Dive profile mode 

             

2.2.6. PC transfer mode 

             

2.2.7. Time set mode

 

             

2-2-8. Dive mode (Gage dive mode)

 

             

2.2.9. Gage Mode

 

             

 

III. 

Technical Specifications

 

 
III. BCD COMPONENTS 

 
IV. USING YOUR BCD / CARE AND MAINTENANCE 

 

 

V. BUOYANCY 
 
VI. WARRANTY

 

 
 
 
 
 
 
 
 
 
 
 

______________________________     

IST PROLINE

 

 

 

I. General information 

 
IST GP-3000 DATA + is a smart, lightweight wrist-top dive computer that provides all the 
essential information a diver will need. Upon self-activation underwater, this sophisticated 
unit begins collecting data such as depth, temperature and dive time at a regular interval and 
by taking air / Nitrox level input by the diver into calculation, the advanced software 
automatically gives precise nitrogen saturation level in the body. Along with other diving and 
safety specific data (ascent rate, partial oxygen level, safety stop timer), all are displayed on a 
large, easy to read screen.   
 
Data+ Dive Computer performs decompression diving calculations using algorithms developed 
by Mr. C. Randy Bohrer based on Swiss-model theory and research. It is intended for use by 
individuals who have completed a recognized scuba diving course.   
 
Despite the complex design, DATA + is incredibly user friendly: its simple, 3-button interface 
lets the diver easily input information and change between 7 different primary functions, 
anytime before, during or after a dive.   
 
Before using IST GP-3000 DATA +, it is imperative to read and understand the whole content 
in order to get the most benefits from using the dive computer, and to avoid risking any 
unnecessary injuries or even death. 
 

Caution! 

 

Persons who have not taken scuba diving training or who are not aware of the risks of scuba 

diving should not use this unit. 

 

You can use Data+ for Nitrox diving where you may set the gas mixture in your tank. 

However, individuals who do not understand Nitrox diving or have not taken training in it 
should not use the NITROX function at all. Also, it is very dangerous to set the mixture on 
the dive computer at a different value than the mixture in the tank. Always reset each time 
you dive and never dive with the incorrect settings. 

 

Data+ is for recreational use and not for professional use. 

 

Data+ is designed with the assumption that you will be doing no-decompression diving. It 

also provides decompression diving data just in case, but this is dangerous and should be 
avoided. 

 

Standard settings in this dive computer assume the user is of average physical strength and 

in reasonable health. When diving with Data+, the diver should therefore dive responsibly 
and make a safe diving plan suited to him or herself. 

Содержание GP-3000 DATA+

Страница 1: ...DIVE COMPUTER www istsports com...

Страница 2: ...by individuals who have completed a recognized scuba diving course Despite the complex design DATA is incredibly user friendly its simple 3 button interface lets the diver easily input information an...

Страница 3: ...straps 328mm 12 9 Wight 115g 4oz Battery CR2032 lithium button battery Maximum depth 99m 328ft PC Connectable Yes interface sold separately II Operational modes 2 1 General This product is the NITROX...

Страница 4: ...Battery indicator icon This displays the current battery power reserve status in voltage When battery voltage is 2 8V or above battery Icon is not shown When battery voltage is 2 6 to 2 7 V battery I...

Страница 5: ...5 seconds B Press this switch to move to dive set mode but if surface time is less than 10 minutes the mode moves to dive plan mode not dive set mode In gage mode move to gage dive set mode display bu...

Страница 6: ...tting of MIX2 B Press this switch to move to dive plan mode In gage mode press this switch to move to dive log mode C Press this switch to change setting the contents C Press and hold this switch to c...

Страница 7: ...leted See the section describing profile mode for further description of log data and profile data The logged data is described below Battery indicator Icon This Icon the current battery voltage Log n...

Страница 8: ...switch to change log number 60 1 60 2 2 1 2 2 1 1 1 2 A Press and hold this switch to change log number fast scrolling The oldest data stop 60 1 59 1 3 1 2 1 1 1 B Press this switch to move to dive p...

Страница 9: ...set for MIX1 or MIX2 which was used while diving It blinks if the MIX1 and MIX2 setting is the default setting Button functions Auto count up dive time The display automatically goes ahead dive time A...

Страница 10: ...ndicator Icon This displays the current battery voltage Mode display This shows Time set mode Operation of switches A Press this switch to select mode second minute hour year month day 12 24 tense sec...

Страница 11: ...ion water temperature measurement and dive time measurement functions Calculation functions such as PGT and OLI etc are not performed If you use this mode when diving it is the GAGE mode until 48 hour...

Страница 12: ..._________________________ IST PROLINE Push and hold C switch When user pushes and holds a switch C it displays the temperature the dive time the maximum water depth and setting FO2 value Dive time Thi...

Страница 13: ...the display and the alarm There are two types of warnings as described below a Graph value 7 It informs with the display and the alarm This information is not recorded in the dive log b Graph value 8...

Страница 14: ...iolation lock display EL back light is on from 4 5 seconds ______________________________ IST PROLINE Water detection switch no function Out of measurement range condition All display segments blink A...

Страница 15: ...cifications Accuracy Time average monthly variance 30 seconds Depth 3 0 5m 3 2ft Temperature 2 0 4 F Measurement range Depth 0 0 99 9m 0 0 328ft In gage mode 0 0 199 9m 0 0 656ft Uses saltwater as sta...

Страница 16: ...1 8 1 8 1 8 1 8 1 8 1 8 1 8 1 second Sound Pattern ON OFF 3 seconds ON 9 seconds 3 second 3 seconds 3 seconds Maximum depth Alarm sounds for 5 seconds EL back light Dive time alarm sounds for 5 secon...

Страница 17: ...compression diving Always make a safety stop at three to six meters if you dive to 15 meters or deeper We also recommend that if the computer tells you to make a decompression stop you should stop for...

Страница 18: ...This occurs when the altitude rank is over 6000m and the altitude mark blinking It will recover when you return to a lower altitude In other cases this may indicate damage Return to manufacturer for r...

Страница 19: ...the relevant department as Seiko Epson in exchange for a replacement product In the event that a defective product is discovered your company will promptly contact Seiko Epson concerning the product a...

Отзывы: