Default warning: When the MIX1 is set at the default value, an alarm will sound when dive
mode starts. It blinks even if it moves to dive mode until it sets MIX1, it continues to blink.
<Default warning>
Button functions
<Non-decompression>
•
A: Press this switch to change to MIX from 3-4 seconds. And EL back light is on from 4-5
seconds.
•
B: EL back light is on from 4-5 seconds.
•
C:When user pushes and holds a switch C, it displays the temperature, the dive time, the
maximum water depth and setting FO
2
value. And EL back light is on from 4-5 seconds.
•
Less than 1.5 m water detection switch OFF: moves to time mode.
<Decompression/Decompression stop violation>
•
A: Press this switch to move to MIX change from 3-4 seconds. And EL back light is on from
4-5 seconds.
•
B: EL back light is on from 4-5 seconds.
•
C:When user pushes and holds a switch C, it displays the temperature, the dive time, the
maximum water depth and setting FO
2
value. And EL back light is on from 4-5 seconds.
•
Less than 1.5 m and after 10 minutes: moves to Decompression stop violation lock. The
computer can’t use for 48 hours. The mode will be automatically switched to time mode after
48 hours have elapsed.
<Decompression stop violation lock>
This mode is locked until 48 hours have elapsed. It can’t move to dive plan mode.
•
A: Press this switch to select place you want to change. And when decompression stop
violation lock display, EL back light is on from 4-5 seconds.
•
B: This switch is mode select switch.
decompression stop violation lock
→
Dive log mode
→
Dive profile mode
→
PC transfer mode
→
decompression stop violation lock
→……
•
C: Press this switch to change setting the contents. And when decompression stop violation
lock display, EL back light is on from 4-5 seconds.
______________________________
IST PROLINE
Water detection switch: no function.
<Out of measurement range condition>
All display segments blink.
•
A: Press this switch to move to Mix change from 3-4 seconds. And EL back light is on from
4-5 seconds.
•
B: EL back light is on from 4-5 seconds.
•
C: When user pushes and holds a switch C, it displays the temperature, the dive time, the
maximum water depth and setting FO
2
value. And EL back light is on from 4-5 seconds.
•
Less than 1.5 m water detection switch OFF: moves to lock condition.
<Out of measurement range lock>
This mode is locked until 48 hours have elapsed. All display segments blink in time mode.
It can’t move to dive plan mode, dive set mode time set mode.
•
A: Press this switch to select place you want to change. In time mode, display, EL back light
is on from 4-5 seconds.
•
B: This switch is mode select switch.
Time mode
→
Dive log mode
→
Dive profile mode
→
PC transfer mode
→
Time mode
→……
•
C: Press this switch to change setting the contents. In time mode, EL back light is on from
4-5 seconds.
•
Water detection switch: no function.
<Gage dive mode>
•
A: EL back light is on from 4-5 seconds.
•
B: EL back light is on from 4-5 seconds.
•
C: When user pushes and holds a switch C, it displays the temperature, the dive time, the
maximum water depth. And EL back light is on from 4-5 seconds.
•
Hold switch C: When user pushes and holds a switch C, it displays the temperature, the dive
time, the maximum water depth.
•
Less than 1.5 m water detection switch OFF: moves to time mode.
2.2.9. Gage Mode
The only functions that can be performed in this mode are the depth calculation, water
temperature measurement, and dive time measurement functions. Calculation functions (such
as calculation of PGT, OLI etc.) are not performed. If you dive in this mode for 3 minutes or
longer, this information will be recorded in the dive log and profile mode.