![IST DCM 1200 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/ist/dcm-1200/dcm-1200_instruction-manual_2094130027.webp)
T
he
reference
in
surface
TreaTmenT
International
Surface
Technologies
i s t s u r f a c e . c o m
27
DCM600 to 1800 - Instruction Manual
Caution:
Always install and maintain this device when the device is turned off and with a
locking installed if necessary. Voltage line will be exposed naked in the output connector / power
and the fuse. For this reason, we installed a protective plastic to protect the user from accidental
contact with the exposed part.
please note that the protective cover supply is a safety device and should be removed for any reason.
For ease of installation and maintenance, connectors and fuses were left unprotected. The design of the
open framework of the DCT1000 requires an enclosure that meets the appropriate safety and local code
requirements. For optimal performance, the enclosure must also protect the controller from dirt, water and
direct sunlight. There are no special requirements for orientation, and the controller is easily mounted using
the mounting holes on the base plate factory installed.
Caution:
Do not place the control cables, communication cables, or other Class 2 wiring in the
same conduit as power cables.
There may be a system malfunction if the Class 2 wiring is placed too close or with the power
conductors
DIMEnSIonS AnD SIzE
sequential Controller (sPeCs & installation)
1.0 — installing tHe dCt1000