13
3.2.4.4 External Amplifier(P0_0)
Support to indicate that audio outputs with an external amplifier by the pin P0_0.
3.3 Function Settings Page
=>
Pressing the Next button on Main Features described above will pop up Function Settings page. Function Settings provides
more detailed configurations. The settings of Main Features will affect some parameters on Function settings page. Base on the
settings of Main Features, some detailed configurations may be fixed or reduce selections. For example, once a profile is
disabled in the configuration of supported features, all settings related to this profile will be canceled.
And there is a button in bottom left corner that can back to Main Features if something need to change. When the editing was
done, pressing the Finish button in bottom right corner to back to Start Menu described above. Then you can save the editing
as a UI parameter table.
There are so many parameters in Function Settings page you can get more information in the next chapter. Function Settings
3.4 Power Switch Setting
The power switch configuration has four types and determines which pattern is used in n-SPK. These four types are listed as
below.
3.2.1 MFB Power ON/OFF
Turning on and turning off n-SPK depends on the duration of pressing MFB button. The related settings are Power On Duration
and Power Off Duration. That is, if users keep pressing MFB key over the configurable time, n-SPK will be turned on or turned
off. Please refer to 4.9.1 Button Press Duration for more information.