(3, da9s1e, 7a5802340b408637 4b58f26e0000fe45, UP, softfail=0, ssd=0),
(4, da8s1e, 46a0fc0443b7f537 4b58f26e0000fe49, UP, softfail=0, ssd=0),
(5, da7s1e, 20a7f22616174ba3 4b58f26e0000fe4d, UP, softfail=0, ssd=0),
(6, da6s1e, 3949624b7b8a2d9d 4b58f26e0000fe51, UP, softfail=0, ssd=0),
(7, da5s1e, 27a1f7ac4657dfda 4b58f26e0000fe56, UP, softfail=0, ssd=0),
(8, da4s1e, 59198b8b1237d60f 4b58f26e0000fe5a, UP, softfail=0, ssd=0),
(9, da3s1e, 3ea11ef23fc52232 4b58f26e0000fe60, UP, softfail=0, ssd=0),
(10, da2s1e, 25bebd5106739b19 4b58f26e0000fe66, UP, softfail=0, ssd=0),
(11, da1s1e, 213df93176467a83 4b591956000cf778, UP, softfail=0, ssd=1)}
8. In the system output from the preceding step, verify that the
ssd
value for the drive is set to
1
.
9. On the front panel, replace the existing 5400S model nameplate with the new 5000S-SSD nameplate.
10. Attach the new 820-0001-01 SKU label over the existing SKU label.
Note: Be sure to cover the lower SKU label, as shown in the following figure. Do not cover the upper
serial number label.
2
1
1 Existing SKU label
2 Replacement SKU label
Figure 6. Replacing the SKU label
11. Repeat steps 1-10 until all nodes on the cluster have been updated with SSDs. When all of the nodes have been
updated, continue to the next step.
12. From any node on the cluster, perform the following actions.
These actions will be applied to all nodes on the cluster:
1. Run the following commands:
sysctl efs.bam.layout.min_free_drive_blocks=3000
echo efs.bam.layout.min_free_drive_blocks=3000 >> /etc/mcp/override/
sysctl.conf
Running these commands prevents a known issue in which ENOSPC errors are incorrectly reported if SSDs fill
with metadata while space is available on other drives. For more information, see Isilon knowledgebase article
201026.
2. Update the image of the node that appears in the web administration interface by running the following command:
isi_for_array 'cp /usr/local/www/ui/images/hwIQ5400S.jpg /usr/local/www/
ui/images/hwIQ5000s-ssd.jpg'
3. Restripe the metadata to the SSDs by running the following command:
isi restripe start autobalance high
13. Record all of the node serial numbers and new system configuration numbers in the Salesforce case.
14. Pack the SAS drives that were removed from the nodes into the SSD drive boxes, apply the shipping labels, and ship
them to Isilon.
on page 5.
Hard drives
©
2010 Isilon Systems, Inc.
17
Содержание IQ S Series
Страница 1: ...Isilon IQ S Series Field Replacement Manual August 2010 120 0031 01 Rev C ...
Страница 4: ...Chapter 11 Air baffle 39 Removing the air baffle 39 Installing the air baffle 40 ...
Страница 8: ......
Страница 18: ......
Страница 22: ......
Страница 26: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......