Chapter 5 Troubleshooting
ID NO.
TITLE ERROR
CONTENTS
SOLUTION
0485 AUXILIARY
FOR
MAGNETIC
CONTACT IS
ABNORMAL
A sub connecting problem of electro
magnetic unit
Contradiction between “status for
the sub connecting of electro
magnetic unit that controls power
line” and “status for emergency
button or covers being out/close”
happened during the wrapping or
happened for more than 5 seconds
when the machine is not moving.
Ex .It happens when the power line
does not shut down In spite of the
cover being open.
<SUB ERROR>
0000:Electro magnetic got shut off in
spite of all the cover being
closed.
0128:Elegro magnetic got shut off in
spite of the emergency button
being released.
[RETURN]
This error tends to happen when the
cover is not closed completely.
<Check Point>
1. Connection of emergency stop [S2]
2. Connection of electro magnetic unit
[K1]
3. Connection of XJ9 of P-1004
0492 FILM REMOVAL IS
COMPLETED
Film removal is completed.
Remove the film following the below
steps.
1. Press emergency stop button.
2. Remove
film.
3. Release emergency stop
button.
[OK]
If there is remaining film, the message
to encourage the user to remove the
film is displayed and [OK] is not
accepted.
0493 REMOVING FILM
Removing film
Receiving a return request (when
film removal is needed) or a film
removal request, the machine
started film removal operation.
When it completes the film removal, it
clears automatically.
5-23
Содержание WM-NANO
Страница 6: ...Introduction 6 ...
Страница 10: ...Chapter 1 Overview 1 2 Part Names 1 2 1 Appearance 1 4 ...
Страница 11: ...Chapter 1 Overview 1 5 ...
Страница 64: ...Chapter 3 Adjustment Mode 10 Remove the cover by turning it from the bottom 3 11 ...