Chapter 3 Adjustment Mode
3.2.8
Adjusting Left and Right Squeezing Plates Widening Amount
Adjust the widening amount between the left and right squeezing plates to 366 – 369 mm.
1
)
Touch the [UNIT TEST] in the Adjustment
Mode.
2
)
Select [LEFT/RIGHT FOLDERS] and touch
[EXECUTE.]
3
)
When the left and right squeezing plates reach the both ends, check that their widening amount is 366
– 369 mm.
4
)
If the widening amount is not 366 – 369, adjust the amount with screws (2) on the detection plate
attached on the left squeezing plate.
Left and right
squeezing plates
Widening amount: 366 –
369 mm
Left squeezing plate
Screws (2)
Detection
plate
3-51