3-2 Refilling lubricant
Always keep the lubricant level between HIGH mark and LOW mark. If the lubricant
level falls below LOW mark, the lubrication unit will send an alarm signal to the control unit
of the machine (option). Remove the cap (Fig. 3) and refill with new clean lubricant.
Warning!
Never use used lubricant
4 Maintenance
iSHAN centralized lubrication system is easy to maintain. Filling new clear grease is the
best maintenance.
5 Faults / Troubleshooting
Warning
!
Disconnect the product from main power supply before working on it..
Warning
!
Please do not try to repair or disassemble the lubrication unit for the faults
not listed below. You should consult and inform
iSH
AN
company at once.
Fault
Possible cause
Recertification
Motor runs
but doesn’t
feed oil.
Motor failure
Return to iSHAN or iSHAN agent
No lubricant
Refilling lubricant(See 2-4.2)
。
Air in the centralized
lubrication system
Vent centralized lubrication system. (See
2-4.5)
。
Pipe blocked or
broke
Disconnected the pipe from the output adapter
to visual check if discharging from the
lubrication unit. If so, the lubrication
functions. Check where it blocked or broke in
the delivery pipe and repair.
Impermissible
lubricant
Remove lubricant from entire system and
dispose of lubricant in the proper manner; fill
system with suitable lubricant. See 2-4.2)
。
Insufficient
oil delivery
Impermissible
lubricant
Remove lubricant from entire system and
dispose of lubricant in the proper manner; fill
system with suitable lubricant.(See 2-4.2)
。
Leaking
Error installation
To avoid any leaking during running service
time, it should be observed up to 1mm
distance between the tube end to the double
sleeve. (See 2-4.3)
。
Wrong tubing option
Recommend metal pipe or high pressure
plastic pipe.