3. V364 RFID SYSTEM WIRING:
2 DOORS CONTROLLER CONNECTION EXAMPLE
Devices consumption:
- ATLAS = 10 W
- Stylos = 3W
Suggested configuration for 2 doors
controller: max 4 Stylos readers.
ATLAS DIN
PoE
Console
Battery
ON
Reset
W
ake up
Switch OFF
ON
GND
+5V
+V OUT
OUT 1
IN 1
GND
Analog IN
GND
+V Power
GND
SER. A
SER. B
COM
NO
NO
COM
R
USB
CH0
Relay
1
Relay
2
IN 2
IN 5
IN 3
IN 4
GND
+5V
R 1
R 3
LED 2
LED 1
R 2
R 5
R 4
+V Power
GND
SER. A
SER. B
CH1
AUX
+V Power
GND
SER. A
SER. B
CH2
Power IN
12 VDC - 800 mA
24 VDC - 400 mA
MADE IN ITALY
PoE
To PoE Switch
(IEEE 802.3af
up to 15,4W)
12 VAC
12 VAC
DOOR 1
Back side view
circuit board
DOOR 1 IN
(Stylos cod.5E1310126)
S1
DOOR 2
Total LOCKBUS channel cable length (sum of all
branches): MAX 100mt.
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
Cable 3 x 0,75mm - AWG 18 (
the calculation of the
cables section must be verified by qualified staff).
WIRING SPECIFICATIONS
LOCKBUS
(+) V ALIM
( ) GND
DOOR 2 IN
(Stylos cod.5E1310126)
Back side view
circuit board
Back side view
circuit board
DOOR 1 OUT
(Stylos cod.5E1310126)
S1
DOOR 2 OUT
(Stylos cod.5E1310126)
Back side view
circuit board
2
Wires colors reported in the wiring diagrams are just an example.
For the Stylos address configuration refer to the
Stylos Installation Guide, available at:
iseo.com
.