iPC25 operating instructions
Page - 9
4.2 Performing system recovery
5
Maintenance and repair
Maintenance
The industrial PCs of the iPC series are maintenance-free.
Cleaning
Switch off the control computer and the connected components and remove the
power supply.
Use a damp, soft cloth for cleaning. Do not use detergents or abrasive cleaners. Be
careful not to allow moisture to enter the housing through the ventilation slots.
1) After you have set the boot medium or the boot-
sequence, start the computer again.
2) If the USB stick does the booting, a "Blue"
cube is displayed on the screen and below this a rotating circle ".
3) After loading the operating system, a command line starts
and then the Windows® Embedded Standard 7 Recovery Wizard.
4) Follow the wizard's instructions. Click on the last
window on the "Install" button to start the recovery.
After successful recovery, a wizard window is displayed. Confirm with OK!
5) Remove the USB Stick (Recovery Stick).
6) Now in the still open command line window, enter the command
<exit> to close the window. The computer will now start again
Содержание iPC25 - F
Страница 1: ...iPC25 F Operating instructions ...
Страница 15: ......