background image

iPC25 operating instructions 
 

Page - 8 

4

 

Recovering the operating system Windows® Embedded Standard 7 

 
Important information 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
4.1 Preparations for restoring the operating system. 

Backing up user data 

 

 

 

 

 

 

 

 
 

 

 
 

 

 

 

Preparing USB Boot

 

  

 

 

 

 
 

 

 

1) To restore the Windows® Embedded operating system 

Standard 7 of your control computer, you need the USB Recovery Stick supplied. This 

data carrier contains an image of the operating system of your installed control 
computer in the delivery state. 

2) The hard disk of the control computer delivered is set to two partitions  

     in the factory The primary partition (approx. 40 GB) of the hard disk contains   
     the operating System Windows® Embedded Standard 7, while the second  

     partition for user data is available. 

3) If you have partitioned the hard disk other than in the delivery state, 
     this will be returned to the delivery state when restored. 

     I.e only the partitions described under 2.) are created. 

 

1) Back up your user data from all partitions to an external 

     data carrier (USB stick, USB HDD). 

2) If you have made changes to the control configuration of your software since the  
    delivery please back up your current control configuration with the CNC  

    wbBackup wizard. This is located within the CNCworkbench entry in the Start     
     menu. Also save this backup on the external disk! 

 

The backup must be done on an external data carrier, 
since when restoring the operating system all partitions 
are formatted and thus all data is lost.

 

1) After you have backed up all the data, you must use the operating system of the 

recovery USB stick supplied.  Plug the USB stick into an available USB port on the 
computer. Switch on the computer and press the <

F12

> key at the beginning of 

the boot process. 

     

 The boot menu of the computer is displayed. 

2) Use the <Up / Down arrow keys> to select the USB stick in the list 
     Confirm your selection with the <

ENTER

> key. 

3) If you have set everything correctly, do not boot the installed 
     operating system but the operating system on the USB Stick. 

 

Alternatively, you can also use the <

Delete

> key in the system start to call up 

the BIOS of the computer There you have to change the boot sequence and set 

the USB Recovery Stick as the first boot medium. After saving the settings, the 

operating system is now started on the Recovery Stick. 

 

Содержание iPC25 - F

Страница 1: ...iPC25 F Operating instructions ...

Страница 2: ...ications may be reproduced in any form print photocopy or any other process without the written permission of isel Germany AG or processed reproduced or distributed using electronic systems The information contained in this manual is subject to change without notice The contents are subject to change without notice Manufacturer isel Germany AG Bürgermeister Ebert Straße 40 D 36124 Eichenzell Tel 0...

Страница 3: ...notices 1 2 Product description 2 2 1 Technical data 2 2 2 Interfaces iPC25 F 4 3 Assembly and start up 6 3 1 Installation dimensions 6 3 2 Switching on the control unit 7 4 Recovering the operating system Windows Embedded Standard 7 8 5 Maintenance and repair 9 6 EG Konformitätserklärung 10 ...

Страница 4: ...nd the recognised safety regulations The device may only be used for its intended use The device may only be operated in an impeccable technical condition Faults must be removed immediately Children and unauthorised persons must not operate the device All work must be carried out exclusively by authorised personnel and taking into account the regulations of the electrical industry and accident pre...

Страница 5: ... mm Weight 1 2 kg Ambient temperature 0 C to 35 C Relative humidity max 90 non condensing Protection type IP20 Supply voltage on the interface 8 see 2 2 12 VDC min 100W external power supply 12V 100W required Use Industrial area Home Office area Form Factor Mini ITX CPU AMD GX 222GC Main memory 2xSO DIMM Socket 1 5V 1 35V max 16GB SC DDR 1333 DD3 1600 ...

Страница 6: ...2 mouse 5 x USB 2 0 2 x LAN 1GBit 2 x serial Port RS 232 1 x Sub D9 pin connection for iBP10 iBP17 iOP 19 TFT Audio Line in Line out 12 V DC power supply internal PCI Express x4 Slot 1 x Mini PCI Express Slot x4 incl USB2 0 USB 2 0 USB 3 0 channels LVDS Dual Channel Backlight Inverter other internal connections see data sheet Mainboard Optional connections USB DVI I VGA interface DVI I HDMI via In...

Страница 7: ...ocket for network 4 USB interfaces 4 x USB 2 0 interfaces for the connection of peripherals 5 Mouse Keyboard Connection Connection socket for mouse and keyboard 6 Audio connection Jack socket Line In Line Out 7 1 x CAN connection CAN Bus connection RJ45 optional CAN Duo 2 x separate CAN Bus 8 Connection of the power supply for cabinet mounting with 2 core cable 12VDC white GND brown 12 VDC 100W su...

Страница 8: ...T GND 8 n v 9 HDD LED GND Connection for HDD power indicator LED GND Power supply for computers and monitors only possible in connection with a sufficiently dimensioned power supply with iBP10 iBP17 iOP 19 TFT at least 100W 10 Multifunction screen for additional optional connections 11 Connector for power supply 2 pin plug when used with external plug in power supply 12 VDC 5A hollow plug 5 5 2 5m...

Страница 9: ...e for the air circulation on the ventilation slots of the iPC Failure to observe this measure will result in overheating and possible defects in the control computer Avoid as far as possible extreme environmental conditions Protect the PC from dust moisture and heat The ventilation slots of the PC must not be covered Scale drawing iPC25 F ...

Страница 10: ... is the default setting in the BIOS of the computer On delivery the IPC25 computers are set up so that the standalone start up is disabled The BIOS setting can be found under POWER Power Failure Recovery Important notice If the start up of the control computer is set up in the BIOS when the supply voltage is applied the computer must be shut down properly before the machine is switched off Otherwi...

Страница 11: ...s to the control configuration of your software since the delivery please back up your current control configuration with the CNC wbBackup wizard This is located within the CNCworkbench entry in the Start menu Also save this backup on the external disk The backup must be done on an external data carrier since when restoring the operating system all partitions are formatted and thus all data is los...

Страница 12: ...you have set the boot medium or the boot sequence start the computer again 2 If the USB stick does the booting a Blue cube is displayed on the screen and below this a rotating circle 3 After loading the operating system a command line starts and then the Windows Embedded Standard 7 Recovery Wizard 4 Follow the wizard s instructions Click on the last window on the Install button to start the recove...

Страница 13: ...tigkeit gegen Entladung statischer Elektrizität ESD EMC Testing and measurement techniques Electrostatic discharge immunity test EN 61000 4 4 2012 EMV Prüf und Messverfahren Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgrößen Burst EMC Testing and measurement techniques Electrical fast transient burst immunity test EN 61000 4 5 2007 EMV Prüf und Messverfahren Prüfung der St...

Страница 14: ...he operating instructions of the computer If this is not the case please send this recovery stick back to us and we will install the Windows image on your stick This means that you can reset your computer to the delivery status at any time This will save you time and money IMPORTANT For repairs to computers always include the recovery stick that matches the serial number When returning a computer ...

Страница 15: ......

Отзывы: