background image

 7

   

8

Front CSD 405-IMC

Safety information

l

l

l

l

l

l

l

l

l

l

l

The 4-axes step motor controller may 
only be used to drive 2-phase step 
motors of up to 60VA. Any other 
utilization or a utilization exceeding 
this specification is considered to be 
non-conformant.

The controllers are designed 
according to the state of the art and 
the acknowledged safety-relevant 
regulations.

The resources may only be operated 
when they are in a perfect technical 
condition. Malfunctions must be 
removed immediately. Children and 
persons who have not been 
instructed are not permitted to 
commission the unit.

All work is to be carried out only by 
skilled personnel and in 
consideration of the regulations of 
the electronics industry and the 
regulations for prevention of 
accidents. Connection and assembly 
work may only be carried out when 
the device has been disconnected 
from the mains.

Do not operate the controller without 
connection to ground.

Before opening the unit, disconnect 
the unit from the mains and pull off 
the mains plug. Not all parts alive are 
covered.

Installation and operation of the 
resources must be performed 
according to the standards of the 
Declaration of Conformity. The 
regulations and limiting values that 
have been observed by the 
manufacturer are not a protection if 
the resources are used improperly.

Ambient temperature 0 to +40°C 
storage temperature 10 to +70°C

Do not expose the unit  to high 
humidity, strong vibrations or 
explosive gasses.

A low impedance potential 
equalization of the machine and 
control system are required to 
comply with the EMC limiting values.

Keep these operating instructions 
carefully and take care that every 
operator adheres to the instructions. 
Inobservance of the operating 
instructions may result in damage to 
property, serious personal injury and 
death.

.

Emergency Stop

POWER-button

POWER

Rear CSD 405-IMC

Power switch, 2-line

Miniature fuse 2.5 A tr.
(miniature fuse 5x20mm,
IEC 127-2)

Power supply 
connector

23

0V

Note

:

The supply voltage 
of the controller can be
coded internally to

     

AC 120V

 

Pressing this button activates the lock of 
the integrated power relay and switches 
on the voltage supply of the step motor 
power output stage.

In the operation mode “POWER ON” the 
POWER lamp lights up.

Operating the emergency stop 
pushbutton off the voltage supply to the 
output stage.

To unlock the switch pull the button out 
of its lock-in position.

START

Initiates the program 
sequence of the controller 
after a stop command.

Pressing the Start button in 
the storage mode starts the 
stored program sequence.

Interrupts the program 
sequence of the controller 
and hence the step output to 
the step motors.

 7

   

8

STOP

systro

 

GmbH

  

Sachsenweg 8     D-36132 Eiterfeld

Tel.: (0 66 72) 898 620     E-Mail:  [email protected]

l

l

l

l

  www.systro.de

l

RS 232

(

)

9-pin Sub-D pin plug

The serial interface is used to program 
the controller.

5

1

9

6

--
--
--
--

Gnd
RxD
TxD
--
--

RS 232

Содержание CSD 405-IMC

Страница 1: ...stop circuit according to EN 60204 emergency stop switching element Power button cover switch output 2 freely usable signal inputs 24V active 2 freely usable switching outputs relay 24 switching 50mA 2 AC outputs 1 relay output 5A 1 solid state relay 1 25A Motor connection on the rear via 9 pin Sub D socket plug Dimensions w x h x d 274 x 152 x 300mm Programmable through the software products PAL ...

Страница 2: ...e 0 to 40 C storage temperature 10 to 70 C Do not expose the unit to high humidity strong vibrations or explosive gasses A low impedance potential equalization of the machine and control system are required to comply with the EMC limiting values Keep these operating instructions carefully and take care that every operator adheres to the instructions Inobservance of the operating instructions may r...

Страница 3: ...ncy Stop situation 14 24 13 23 9 14 1 7 Operating mode switches from automatic to test operation 14 24 13 23 4 13 3 6 Cover button unlocks the optional cover switch with tumbler 14 b 13 a 11 10 SK control 15 pin Sub D socket plug E1 A2 A1 E2 E3 A3 E4 A4 bipolar serial bipolar parallel Example 2 phase step motor 8 conductors 4 3 2 1 4 3 2 1 9 7 5 Reference switch Limit systro GmbH Sachsenweg 8 D 36...

Страница 4: ...383025 1000 has been carried out according to the EC Directives Low voltage directive 73 23 EWG 19 02 73 amendment 93 86 EWG 22 07 93 EMV Directive 89 336 EWG 03 05 89 amendment 91 263 EWG 29 04 91 Amendment 2 31 EWG 28 04 92 Amendment 93 68 EWG 22 07 93 Eiterfeld August 16 2003 Rainer Giebel General Manager systro Electronics for systems systro Electronics for systems systro GmbH Sachsenweg 8 D 3...