The 4-axes step motor controller may
only be used to drive 2-phase step
motors of up to 60VA. Any other
utilization or a utilization exceeding
this specification is considered to be
non-conformant.
The controllers are designed
according to the state of the art and
the acknowledged safety-relevant
regulations.
The resources may only be operated
when they are in a perfect technical
condition. Malfunctions must be
removed immediately. Children and
persons who have not been
instructed are not permitted to
commission the unit.
All work is to be carried out only by
skilled personnel and in
consideration of the regulations of
the electronics industry and the
regulations for prevention of
accidents. Connection and assembly
work may only be carried out when
the device has been disconnected
from the mains.
Do not operate the controller without
connection to ground.
Before opening the unit, disconnect
the unit from the mains and pull off
the mains plug. Not all parts alive are
covered.
Installation and operation of the
resources must be performed
according to the standards of the
Declaration of Conformity. The
regulations and limiting values that
have been observed by the
manufacturer are not a protection if
the resources are used improperly.
Ambient temperature 0 to +40°C
storage temperature 10 to +70°C
Do not expose the unit to high
humidity, strong vibrations or
explosive gasses.
A low impedance potential
equalization of the machine and
control system are required to
comply with the EMC limiting values.
Keep these operating instructions
carefully and take care that every
operator adheres to the instructions.
Inobservance of the operating
instructions may result in damage to
property, serious personal injury and
death.
.
Emergency Stop
POWER-button
POWER
Rear CSD 405-IMC
Power switch, 2-line
Miniature fuse 2.5 A tr.
(miniature fuse 5x20mm,
IEC 127-2)
Power supply
connector
23
0V
Note
:
The supply voltage
of the controller can be
coded internally to
AC 120V
Pressing this button activates the lock of
the integrated power relay and switches
on the voltage supply of the step motor
power output stage.
In the operation mode “POWER ON” the
POWER lamp lights up.
Operating the emergency stop
pushbutton off the voltage supply to the
output stage.
To unlock the switch pull the button out
of its lock-in position.
START
Initiates the program
sequence of the controller
after a stop command.
Pressing the Start button in
the storage mode starts the
stored program sequence.
Interrupts the program
sequence of the controller
and hence the step output to
the step motors.
7
8
STOP
systro
GmbH
Sachsenweg 8 D-36132 Eiterfeld
Tel.: (0 66 72) 898 620 E-Mail: [email protected]
l
l
l
l
www.systro.de
l
RS 232
(
)
9-pin Sub-D pin plug
The serial interface is used to program
the controller.
5
1
9
6
--
--
--
--
Gnd
RxD
TxD
--
--
RS 232