3.5
KillEnable
If KillEnable is active, the device switches off the high voltage at the following events without voltage ramp:
•
when an ARC is detected (ARC),
•
output voltage V
OUT
≥
voltage limit V
LIM
,
•
output current I
OUT
≥
current limit I
LIM
,
•
when the device is switched to the constant current source CC operating mode
The display shows "KILL" in the status line.
4
Pinout
Figure 4.1: Back panel of the device
4.1
Supply
The unit is connected to mains net using the power connector on the back panel.
4.2
HV connection
The unit has one HV output. The HV cable has to be connected to the load properly and isolated according to proof-voltage.
The shield of the HV cable is always connected to the housing. It can be used as return if the connectors “0V” and “PE” are
short circuited.
4.3
OV connection
If the short circuit between the connectors “0V” and “PE” is removed, as return an additional wire has to be used. This wire
has to connected with “0V”. The potential between the connector “0V“ and the protective ground can be
±
400 V.
Warning!
The user has to ensure that no danger will occur because of the voltage between the connectors
”0V“ and ”PE“!
If the potential between the return conductor and the protective ground will be larger than
400
V then the connectors will be
short circuited via an electronically protection circuit to avoid damages of the power supply.
4.4
IL connection
See section 3.3 Interlock
4.5
Interface connection
See section USB, RS232 interface, CAN interface, IEEE interface, Ethernet interface and AIO interface.
IL
OV
HV