Status Bit
Description when bit is set to 1
Is Voltage Bound Lower
The measured voltage is lower than the programmed lower bound
Is Voltage Bound Upper
The measured voltage is higher than the programmed upper bound
Is Voltage Ramp Down
Voltage is ramping down to a lower absolute value
Is Voltage Ramp Up
Voltage is ramping up to a higher absolute value
Is Current Ramp Down
Current is ramping down
Is Current Ramp Up
Current is ramping up
Is Current Ramp
A current ramp is running
Is Voltage Limit
The measure voltage exceeds the voltage limit V
lim
Is Current Limit
The measured current exceeds the current limit I
lim
Is Current Trip
Either voltage limit or current limit has been exceeded in Kill Enable or current measure
exceeded current set in Kill Enable or Delayed Trip
Is External Inhibit
An External Inhibit is active and prevents turning on the channel
Is Voltage Bounds
The measured voltage is out of the programmed bounds V
bounds
Is Current Bounds
The measured current is out of the programmed bounds I
bounds
Is Arc Error
The high voltage has been shut down because the number of allowed electrical ARCs has been
exceeded
Is Low Current Range
The current measurement value originates from the Low Current Current Range
(for devices with two current ranges only)
Is Constant Voltage
Voltage control is active (evaluation is guaranteed when no ramp is running)
Is Constant Current
Current control is active (evaluation is guaranteed when no ramp is running)
Is Emergency Off
The channel is in state emergency off
Is Voltage Ramp
A voltage ramp is running
Is On
The channel is turned on
Is Input Error
An input error occurred (e.g. a parameter is out of range)
Is Arc
An electrical ARC has occurred recently
Is Positive
The channel has positive output polarity (0 is negative polarity)
SCPI protocol common instruction set | Last changed on: 2020-11-10 |