1.4) COMPONENTS AND FUNCTIONS TEST MENU
This procedure can be used to check the operation of the unit’s components.
Set menu
0015
(see Chap.1.1), confirm with the
S
Key
.
The display shows
tESt 1.
When the
F
Key is pressed repeatedly, the following tests can be selected sequentially:
Test 1
All display segments check.
Test 2
All leds check.
Test 4
Out
C
and keys check.
Test 5
Refrigerant scale net weight visualization.
Test 6
Pressure transducer visualization (mV).
Test 7
Not used
Test 8
Not used
Test 9
Printer test. (If installed)
–
End–
Exit.
Use the
F
Key to select the desired menu.
Confirm with the
S
Key.
Use the
S
Key to exit from the individual tests
.
With the display showing –
End–
, press the
S
Key to exit. The display shows the Stand-by
mode.