SERVICE MANUAL
SYSTEMS
2
1.0) CALIBRATION AND TEST MENU
1.1) CALIBRATION MENU ACCESSING PROCEDURE
WARNING: PERFORM THIS PROCEDURE ONLY AFTER HAVING READ THE
FOLLOWING INSTRUCTIONS CAREFULLY. IF NOT PERFORMED PROPERLY, THIS
PROCEDURE CAN CAUSE MALFUNCTIONING AND DAMAGE THE UNIT.
Supply power to the unit.
With the display showing the net weight available (Stand-by mode), proceed as described
below:
Press the
UP
Key and keep it pressed
.
Press the
S
Key and keep it pressed
.
Release the
UP
Key.
Press the
DOWN
Key and keep it pressed
.
Release the
S
Key.
Release the
DOWN
Key.
The display shows
0000
.
Use the
UP-DOWN
keys to access the following menus:
0001
Refrigerant scale calibration.
0005
Maintenance meter calibration (reset).
0015
Components and functions test menu.
0050
Printer enabling.
0567
Operation parameter setting menu.
Set the desired menu
.
Use the
S
key to confirm.
See the chapters on the individual menus.