background image

8

9

EZYiD

®

 Retro-fit System - Issue A - August 2019

EZYiD

®

 Retro-fit System - Issue A - August 2019

5

 EZYiD

®

 Reader Operation

 5.1 Charging the Reader

Insert the Micro USB into the portal on the back of the EZYiD Reader

Insert the USB into the computer, tablet or other USB charging portal

Flashing Blue Light (when charger cable unplugged) = Battery Low

Flashing Blue Light (when charger cable is connected to device and to 

power source) = Reader is charging

Solid Blue Light (when charger is connected to device and to power 

source) = Reader is fully charged

NOTE:

• The Reader remains fully operational and can be used to read Tags, 

while the device is re-charging

•  As  with  all  battery  powered,  re-chargeable  devices,  the  device 

should be disconnected from the power supply

•  The  EZYiD  Reader  is  fitted  with  a  non-replaceable  battery.    This 

battery is capable of approximately 10,000 reads per charge.

Содержание EZYiD

Страница 1: ...1 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System...

Страница 2: ...examples and diagrams in this manual are included solely for illustrative purposes NOTE Reproduction of the contents of this manual in whole or in part without written permission of CSP Distribution P...

Страница 3: ...information about the features of the Reader how to install configure operate and maintain it together with troubleshooting information Before working with the EZYiD Reader users should familiarise th...

Страница 4: ...Antenna Central Button LED Blue EZYiD Logo Body of Reader LED Orange 7 8 9 10 11 Product Information Label Serial Number Charging Port Identification Numbers Product Regulatory Information Not to Sca...

Страница 5: ...Low Flashing Blue Light when charger cable is connected to device and to power source Reader is charging Solid Blue Light when charger is connected to device and to power source Reader is fully charge...

Страница 6: ...n the central diamond shaped button for one 1 second 2 An orange LED will appear on the right side 3 The LED will move to the left and appear in blue Two 2 beeps will sound The blue LED will remain on...

Страница 7: ...or mobile phone to pair the Reader to your personal device Your Reader can only be paired to one computer tablet or mobile phone at a time in order for it to function correctly If you wish to pair th...

Страница 8: ...le press of the central button the device is on the tag is readable and the reader is able to read the tag but your Reader is not paired to a computer tablet or mobile device Therefore data informatio...

Страница 9: ...ystem Issue A August 2019 5 5 How to Hold the EZYiD Reader The EZYiD Reader should be held comfortably in one hand ensuring that the antenna is not covered Care should be taken not to press hold or da...

Страница 10: ...cated Different LED and sounds will notify you of the outcome Hold the antenna closely 2 3mm over the Tag Sticker Cable Tie or Universal Moulded Tag which needs to be read Press down on the central bu...

Страница 11: ...Application Tags 6mm 2mm Tags Tags are low profile with a depth of 2mm and diameter of 6mm Tags can be applied to assets using a commonly available Contact Adhesive or Two part Epoxy Resin not supplie...

Страница 12: ...System Issue A August 2019 Cable Ties Cable Tie Cable Ties are fitted with an EZYiD Tag near the buckle end of the tie thus allowing the Cable Ties to be fitted in the usual manner with any excess le...

Страница 13: ...ssue A August 2019 25mm 25mm Stickers Stickers Stickers are 25mm x 25mm 1 x1 with a low profile of 1mm and contain a special flat RFID tag Stickers are supplied with a self adhesive backing and can be...

Страница 14: ...t 2019 Universal Moulded Tags Universal Moulded Tags Universal Moulded Tags are 19mm x 10mm x 5mm 3 4 x 25 64 x 13 64 and can be fitted to assets by using a cable tie nail screw pop rivet or glue The...

Страница 15: ...rea of the asset where they will not interfere with the function of the asset Care should also be taken to position the tag away from the high wear areas of the asset in order to best defend the tags...

Страница 16: ...emicals and other environmental conditions that could possibly cause damage to the Reader Damage to the Reader could result in a lack of integrity in operating functions CAUTION The EZYiD Reader case...

Страница 17: ...s connected Consult the dealer RoHS Conformity BlueBerry has been realized using materials and constructive processes conforming to the limits imposed by the directive 2003 108 CE RoHS concerning the...

Страница 18: ...ot use or attempt to use the defective product until CSP Distribution Pty Ltd has had the opportunity to assess the product s defects and respond appropriately to the complaint Any use of the product...

Страница 19: ...responsibility of the user to read and understand these instructions prior to use If the Reader is used in a manner contrary to the specification of the manufacturer as defined in this manual the pro...

Страница 20: ...38 39 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System Issue A August 2019 Notes Notes...

Страница 21: ...carborough Beach Road Osborne Park WA 6017 www ezyid com 61 8 6146 0170 support ezyid com International Safety Components Ltd Unit 1 Plot 2 Llandygai Industrial Estate Bangor Gwynedd LL57 4YH United K...

Отзывы: