Radio Frequency Identification (RFID), is a method of communicating 

information from one point to another point by use of electromagnetic 

waves  (radio  waves).  RFID  Technology  has  unique  characteristics, 

making it beneficial for use in industrial systems. 

The  EZYiD  Reader  is  a  specially  designed  Ultra  High  Frequency 

(UHF) device, designed for use in conjunction with EZYiD RFID Tags, 

Cable Ties, Stickers and Universal Moulded Tags and also with EZYiD 

embedded  hardware  products.  The  Reader  is  designed  to  transfer 

unique serial number information from the tag to a computer, tablet or 

mobile phone device of the user’s choice. 

The  EZYiD  Reader  User  Instruction  Manual  provides  users  with 

information about the features of the Reader, how to install, configure, 

operate and maintain it, together with troubleshooting information. 

Before  working  with  the  EZYiD  Reader,  users  should  familiarise 

themselves with this manual and that of the device that they wish to 

use the Reader in conjunction with.

It is the responsibility of the seller to provide this instruction manual 

and it is the responsibility of the user to read and understand these 

instructions prior to use.  If the Reader is used in a manner contrary to 

the specification of the manufacturer (as defined in this manual), the  

performance of the equipment may be impaired. 

1

 Introduction to EZYiD

®

2

 Who Should Read this User Instruction Manual?

Attentively  read  all  the  precautions  of  use  and  the  operating 

instructions before use.

NOTE: The Reader device has not been designed for use in processes 

or machineries for the monitoring and the safety of human life or for 

medical treatments.

Precautions of Use

Содержание EZYiD

Страница 1: ...1 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System...

Страница 2: ...examples and diagrams in this manual are included solely for illustrative purposes NOTE Reproduction of the contents of this manual in whole or in part without written permission of CSP Distribution P...

Страница 3: ...information about the features of the Reader how to install configure operate and maintain it together with troubleshooting information Before working with the EZYiD Reader users should familiarise th...

Страница 4: ...Antenna Central Button LED Blue EZYiD Logo Body of Reader LED Orange 7 8 9 10 11 Product Information Label Serial Number Charging Port Identification Numbers Product Regulatory Information Not to Sca...

Страница 5: ...Low Flashing Blue Light when charger cable is connected to device and to power source Reader is charging Solid Blue Light when charger is connected to device and to power source Reader is fully charge...

Страница 6: ...n the central diamond shaped button for one 1 second 2 An orange LED will appear on the right side 3 The LED will move to the left and appear in blue Two 2 beeps will sound The blue LED will remain on...

Страница 7: ...or mobile phone to pair the Reader to your personal device Your Reader can only be paired to one computer tablet or mobile phone at a time in order for it to function correctly If you wish to pair th...

Страница 8: ...le press of the central button the device is on the tag is readable and the reader is able to read the tag but your Reader is not paired to a computer tablet or mobile device Therefore data informatio...

Страница 9: ...ystem Issue A August 2019 5 5 How to Hold the EZYiD Reader The EZYiD Reader should be held comfortably in one hand ensuring that the antenna is not covered Care should be taken not to press hold or da...

Страница 10: ...cated Different LED and sounds will notify you of the outcome Hold the antenna closely 2 3mm over the Tag Sticker Cable Tie or Universal Moulded Tag which needs to be read Press down on the central bu...

Страница 11: ...Application Tags 6mm 2mm Tags Tags are low profile with a depth of 2mm and diameter of 6mm Tags can be applied to assets using a commonly available Contact Adhesive or Two part Epoxy Resin not supplie...

Страница 12: ...System Issue A August 2019 Cable Ties Cable Tie Cable Ties are fitted with an EZYiD Tag near the buckle end of the tie thus allowing the Cable Ties to be fitted in the usual manner with any excess le...

Страница 13: ...ssue A August 2019 25mm 25mm Stickers Stickers Stickers are 25mm x 25mm 1 x1 with a low profile of 1mm and contain a special flat RFID tag Stickers are supplied with a self adhesive backing and can be...

Страница 14: ...t 2019 Universal Moulded Tags Universal Moulded Tags Universal Moulded Tags are 19mm x 10mm x 5mm 3 4 x 25 64 x 13 64 and can be fitted to assets by using a cable tie nail screw pop rivet or glue The...

Страница 15: ...rea of the asset where they will not interfere with the function of the asset Care should also be taken to position the tag away from the high wear areas of the asset in order to best defend the tags...

Страница 16: ...emicals and other environmental conditions that could possibly cause damage to the Reader Damage to the Reader could result in a lack of integrity in operating functions CAUTION The EZYiD Reader case...

Страница 17: ...s connected Consult the dealer RoHS Conformity BlueBerry has been realized using materials and constructive processes conforming to the limits imposed by the directive 2003 108 CE RoHS concerning the...

Страница 18: ...ot use or attempt to use the defective product until CSP Distribution Pty Ltd has had the opportunity to assess the product s defects and respond appropriately to the complaint Any use of the product...

Страница 19: ...responsibility of the user to read and understand these instructions prior to use If the Reader is used in a manner contrary to the specification of the manufacturer as defined in this manual the pro...

Страница 20: ...38 39 EZYiD Retro fit System Issue A August 2019 EZYiD Retro fit System Issue A August 2019 Notes Notes...

Страница 21: ...carborough Beach Road Osborne Park WA 6017 www ezyid com 61 8 6146 0170 support ezyid com International Safety Components Ltd Unit 1 Plot 2 Llandygai Industrial Estate Bangor Gwynedd LL57 4YH United K...

Отзывы: