Page of 13
8
AUXILIARY HANDLE
Operate your power tool only with the auxiliary handle (12).
Rotating the Auxiliary Handle (see figure E)
The auxiliary handle (12) can be set to any position for a secure and low-fatigue working posture.
Turn the bottom part of the auxiliary handle (12) in counter clockwise direction and swivel the
auxiliary handle (12) to the desired position. Then retighten the bottom part of the auxiliary handle
(12) by turning in clockwise direction. Pay attention that the clamping band of the auxiliary handle is
positioned in the groove on the housing as intended for.
Adjusting the Drilling Depth (see figure F)
The required drilling depth X can be set with the depth stop (16).
Press the button for the depth stop adjustment (11) and insert the depth stop into the auxiliary
handle (12). The knurled surface of the depth stop (16) must face downward. Insert the SDS-plus
drilling tool to the stop into the SDS-plus tool holder (3). Otherwise, the movability of the SDS-plus
drilling tool can lead to incorrect adjustment of the drilling depth. Pull out the depth stop until the
distance between the tip of the drill bit and the tip of the depth stop correspond with the desired
drilling depth X.
Removing Drilling Tools without SDS-plus
Turn the sleeve of the key type drill chuck (14) with the drill chuck key in a counterclockwise
direction until the drilling tool can be removed.
Inserting Drilling Tools without SDS-plus (see figure G)
Note:
Do not use tools without SDS-plus for hammer drilling or chiseling! Tools without SDS-plus
and their drill chucks are damaged by hammer drilling or chiseling. Insert the quick change keyless
chuck 1. Firmly hold the retaining ring (18) of the quick change chuck. Open the tool holder by
turning the front sleeve (17) until the tool can be inserted. Tightly hold the retaining ring (18) and
firmly turn the front sleeve (17) in the direction of the arrow until a distinct latching noise can be
heard.
Check the tight seating by pulling the tool.
Note:
If the tool holder was opened to the stop, then the latching noise possibly may be heard while
closing the tool holder and the tool holder will not close. In this case, turn the front sleeve (17) once
in the opposite direction of the arrow. Afterwards, the tool holder can be closed (tightened) again.
Turn the mode selector switch (10) to the “Drilling” position.
Removing Drilling Tools without SDS-plus (see figure H)
Firmly hold the retaining ring (18) of the quick change chuck. Open the tool holder by turning the
front sleeve (17) in the direction of the arrow until the tool can be removed.
OPERATION
Starting Operation
Observe correct mains voltage! The voltage of the power source must agree with the voltage
specified on the type plate of the power tool.
Setting the Operating Mode
The operating mode of the power tool is selected with the mode selector switch (10).
Note: Change the operating mode only when the machine is switched off! Otherwise, the machine
can be damaged.
To change the operating mode, and turn the mode selector switch (10) to the requested position
until it can be heard to latch.
Содержание 32185
Страница 5: ...Page of 13 5...