4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
PLANNING YOUR INSTALLATION
WARNING
Check all local building and safety codes before
installation. The installation instructions and appro-
priate code requirements must be followed exactly
and without compromise. Alterations to the stove are
not allowed. Do not connect the stove to a chimney
system serving another stove, appliance, or any air
distribution duct. Failure to follow these instructions
will void the manufacturers warranty.
The installation of this appliance must conform to local codes and appli-
cable state and federal requirements. Familiarity with these requirements
before installation is essential. Important considerations to discuss with
local building officials include:
1. Applicable codes (i.e. Uniform Mechanical Code, State or Regional
Codes).
Electrical codes:
In USA, NEC, ANSI/NFPA 70 – Latest Edition
In Canada, CSA C22.1 – Latest Edition
2. Local amendments
3. Is a permit required - cost. You may wish to contact your insurance
company to ask if they require this.
4. If outside combustion air is required
5. Rooms where the installation is not allowed
Power Supply Requirements
The power cord must be plugged into a standard, 120 volt, 60 Hz
grounded electrical outlet. The power supply cord must be routed to
avoid contact with any of the hot or sharp exterior surface areas of the
stove. When installed in a manufactured home, the appliance must be
electrically grounded to the steel chassis of the manufactured home (see
Mobile Home Installations on Page 13, for additional requirements).
These requirements must be met unless otherwise specified by state
or local authorities.
Questions To Ask Local Building Official
A correct installation is critical and imperative for reducing fire hazards and
perilous conditions that can arise when wood pellet burning appliances
are improperly installed. The installer must follow all of the manufactur-
ers’ instructions.
WARNING
Electrical grounding instructions: This appliance is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the ground-
ing prong from this plug. Do not route power cord
under or in front of appliance.
Smoke Detector Recommended
Since there are always several potential sources of fire in any home, we
recommend installing smoke detectors. If possible, install the smoke
detector in a hallway adjacent to the room (to reduce the possibility of
occasional false activation from the heat produced by these appliances).
If your local code requires a smoke detector be installed within the same
room, you must follow the requirements of your local code. Check with
your local building department for requirements in your area.
Carbon Monoxide Monitor Recommended
Carbon Monoxide Poisoning: Early signs of carbon monoxide poison-
ing are similar to the flu with headaches, dizziness and/or nausea. If you
have these signs, obtain fresh air immediately. Some people are more
affected by carbon monoxide than others, including pregnant women,
people with heart or lung disease or anemia, those under the influence
of alcohol, and those at high altitudes.
It is against federal regulations to operate wood heaters in a man-
ner inconsistent with operating instructions in the manual.
Surge Protectors
A surge protector is recommended to ensure the stove’s electrical com-
ponents are not damaged due to a surge in the electrical supply. Only
high quality protectors listed to UL1449 should be used - low quality
protectors do not provide the protection needed.
Installation / Maintenance Standards
National Fire Protection Association – The primary NFPA standard that
refers to installation and maintenance of pellet stoves and venting is
NFPA 211 – Latest Edition: Chimneys, Fireplaces, Vents, and Solid Fuel
appliances.
Electrical
• The fireplace insert requires 120 volts AC for operation.
• Maximum wattage is 700.
• Igniter wattage is 400.
• Normal operating wattage is 300.
Electrical Generator Operation
Your Winslow™ PI40GL insert can be powered with a gas driven electrical
generator. However, the generator’s electrical regulator may not be compat-
ible with the insert’s electronics. The higher the quality of the generator,
the greater the chance that it is compatible with the insert.
WARNING
This product can expose you to chemicals includ-
ing Carbon Black, which is known to the State of
California to cause cancer, and Carbon Monoxide,
which is known to the State of California to cause
birth defects or other reproductive harm. For more