13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 12
CONTROL BOARD
36" FIREPLACE OPENING
18"
13-1/2"
FIREPLACE OPENING C/L
19-1/4"
18-3/8"
HEARTH / FLOOR PROTECTION
31-3/4"
11"
7-7/16"
6-11/16"
138°
41" SURROUND WIDTH
2-15/16"
Figure 11B
Manufactured (Mobile) Home Installations
In addition to the standard installation instructions, the fol-
lowing instructions may be required by local, state or federal
building codes. See Figure 12.
• Installation should be in accordance with the Manufactured
Home and Safety Standard (HUD), CFR 3280, Part 24.
• Connecting the Winslow PI40GL insert to outside combus-
tion air is required in manufactured home installations
and when required by local building codes. The insert’s
air intake will accept 2” ID pipe to accommodate outside
air installations. The air intake on the exterior of the home
should always be located a minimum of 18” below the flue
termination and must remain free of obstruction. The inlet
must also have a screen with openings not larger than 1/4”
to prevent rodents from entering.
• The insert must be fastened to the hearth/floor using lag
screws. The screws can be inserted through the holes in
the base located behind the side doors. If the hearth is
concrete or masonry, use proper lag bolts and methods
designed for anchoring to masonry or concrete.
• The insert must be grounded with a #8 or larger copper
wire.
WARNING: DO NOT INSTALL THIS INSERT IN A SLEEP-
ING ROOM IN A MANUFACTURED HOME.
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
CONTROL
BOARD
18"
13-1/2"
FIREPLACE OPENING C/L
21-1/2"
18-3/8"
HEARTH/FLOOR PROTECTION
31-3/4"
11"
7-7/16"
6-11/16"
138°
3"
41" SURROUND WIDTH
32" FIREPLACE OPENING
DEEP
SURROUND
Figure 11C
Fireplace Installation Using Standard Surround Kits
(P/N 79004, 79005, 79006 and 79007)
Fireplace Installation Using 3 Inch Deep ZC Surround Kit
(P/N H7232 *)
* This black surround kit positions the insert 3” forward so that it will allow the insert to fit
into a fireplace with a narrower width in the front (32” min.). NOTE: No trim kits are avail-
able for this kit at this time. See instruction sheet P/N 506033-05 for more information.
Termination Cap
Outside Air Pipe
Listed Pellet Pipe or
Flex Liner
Storm Collar
Flashing