Dip Switch Settings
Before the camera is fixed into place and operated, set the appropriate camera address, protocol and baud rate. This is
done via a bank of dip-switches located underneath a removable cover plate on the under side of the camera (see drawing
on page 5 above and illustration below).
SWITCH BANK ONE: Camera Address Settings
SWITCH BANK TWO: Baud Rate, Protocol and Fixed Image Flip (Upside Down Mode)
Iris Innovations
IM-PTZ-16-INST-DOCv1.1
6
Camera Address
SW1
SW1
SW1
SW1
SW1
SW1
SW1
SW1
Camera Address
1
2
3
4
5
6
7
8
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
…
…
…
…
…
…
…
…
…
253
ON
OFF
ON
ON
ON
ON
ON
ON
254
OFF
ON
ON
ON
ON
ON
ON
ON
255
ON
ON
ON
ON
ON
ON
ON
ON
Switch bank One
Switch bank Two
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW Position
1
2
3
4
Protocol
ON
OFF
OFF
OFF
User
User
User
User
Protocol
OFF
ON
OFF
OFF
PELCO-P
PELCO-P
PELCO-P
PELCO-P
Protocol
ON
ON
OFF
OFF
PELCO-D
PELCO-D
PELCO-D
PELCO-D
Protocol
OFF
OFF
ON
OFF
Reserved
Reserved
Reserved
Reserved
Protocol
ON
OFF
ON
OFF
Reserved
Reserved
Reserved
Reserved
Protocol
OFF
ON
ON
OFF
Reserved
Reserved
Reserved
Reserved
SW Position
5
6
7
8
Baud Rate (BPS)
1200
1200
1200
1200
ON
OFF
OFF
-
Baud Rate (BPS)
2400
2400
2400
2400
OFF
ON
OFF
-
Baud Rate (BPS)
4800
4800
4800
4800
ON
ON
OFF
-
Baud Rate (BPS)
9600
9600
9600
9600
OFF
OFF
ON
-
Baud Rate (BPS)
19200
19200
19200
19200
ON
OFF
ON
-
Baud Rate (BPS)
Reserved
Reserved
Reserved
Reserved
OFF
ON
ON
-
Image Flip
Desktop Installation
Desktop Installation
Desktop Installation
Desktop Installation
-
-
-
OFF
Image Flip
Reverse Installation
Reverse Installation
Reverse Installation
Reverse Installation
-
-
-
ON