Model2310 Ver.14.0
35
8. SPA START-UP and CARE
IMPORTANT
Your spa has passed stringent quality assurance testing by trained technicians to ensure reliability and your long
–term satisfaction. Before filling the spa, wipe the shell clean with a soft dry rag.
Follow these instructions to ensure a successful start-up or refill.
1)
Fill spa to correct level (approximately 4 inches 10 cm above the top of the filter cartridge).
2)
Power up. First the system starts in priming mode the circulation pump starts up automatically do
NOT start
jet pumps or blower
at this stage let the priming mode continue until the control panel display shows
standard mode.
IMPORTANT!
Check for air locks in the circulation pump system, during the priming.
There are five small jets installed in the foot well walls one is the ozonator where there should be a stream of
bubbles coming out, if there is small bubbles coming out from some of the other small jets there is an airlock
in the system check for 30 seconds and if there is still small bubbles do as follows
.
Turn the power off and
follow the instructions on last page in this Manual.
WARNING
DO NOT ALLOW THE PUMPS TO RUN FOR MORE THAN 1 (one) MINUTE WITHOUT WATER FLOWING FROM
THE JETS. PUMPS WITH DRY RUN PROBLEMS WILL NOT BE COVERED UNDER WARRANTY
3)
Once the priming is completed, Re-attach the equipment access panel.
4)
Heating will occur at a rate of 5-12 f or 2-3 .C per hour, depending upon the size of the spa and the electrical
circuit
5)
Add stain and scale control (or a similar product.)
6)
Test and adjust total alkalinity. Run pump for 1/2 hour.
7)
Test and adjust pH. Run pump for 1/2 hour. Test again to ensure stable pH and alkaline levels.
8)
If sanitizing with bromine, add with jets running. (See ―bromine‖ in this section.)
9)
Fill and set bromine floater or adjustable bromine feeder and place in the spa water.
10)
Shock water using potassium peroxymonosulfate while jets are running.
11)
If sanitizing with chlorine, use only a granular ―Dichloride‖ compound. On start up, turn on all jets, add 1 oz.
per 500 gal. spa water. Check free available chlorine (FAC) to attain 2-3PPM. Repeat of needed. For regular
use, turn jets on, scatter 1/2 oz. per 500 gal. to spa water to maintain 2-3PPM of FAC. (See ―chlorine‖ in this
section.)