Model2310 Ver.14.0
18
example, the Left arrow button is matched the Jets2 Icon. Directly press the Left Arrow button to control the
pump2, The control way is same to the left control buttons on the panel.
(c )General Messages
Most messages and alerts will appear at the bottom of the normally used screens. Several alerts and messages
may be displayed in a sequence.
Some messages can be reset from the panel.
Messages that can be reset will appear with a ―right arrow‖ at
the end of the message. This message can be selected by navigating to it at pressing the Select button.
The water is too hot – M029
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa functions are disabled. System
will auto reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or
high ambient temp. This message can be reset from the topside panel.
Possible freezing condition
A potential freeze condition has been detected, or the Aux Freeze Switch has closed. All water devices are
activated. In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
– – –°F – – –°C
Water Temperature is Unknown
A
fter the pump has been running for 1 minute, the temperature will be displayed.
Heater-Related Messages
The water flow is low – M016
There may not be enough water flow through the heater to carry the heat away from the heating element. Heater
start up will begin again after about 1 min. See ―Flow Related Checks‖ below.
The water flow has failed* – M017
There is not enough water flow through the heater to carry the heat away from the heating element and the heater
has been disabled. See ―Flow Related Checks‖ below. After the problem has been resolved, you must press any
button to reset and begin heater start up.
The heater may be dry* – M028
Possible dry heat, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any button
to reset the heater start-up. See ―Flow Related Checks‖ below.