TABLE 2 - Minimum clearances
TABLE 1 - Connections
6
1.1
INTRODUCTION
COMFORT 30
are premixed gas
condensation thermal modules that
employ a microprocessor-based
technology to control and manage
all the functions.
All modules are compliant with
European Directives 2009/142/CE,
2004/108/CE, 2006/95/CE and
92/42/CE. For optimum installation
and operation, always follow
the instructions provided in this
manual.
The products manufactured and
sold by
do not contain any
banned materials or substances (ie
they comply with ISO9000:2000).
1 DESCRIPTION OF THE BOILER
65
65
60
70
=
=
M
U
G
E
R
M U G
E
R
125
15
450
ø 60/100
139
183
50
39
30
10
63
S3
S
96
15
16
4
97
750
S3
290
Fig. 1
1.2
DIMENSIONS (fig. 1)
For
servicing
ABOVE THE APPLIANCE CASING
200 mm
AT THE R.H.S.
15 mm
AT THE L.H.S.
15 mm
BELOW THE APPLIANCE CASING
200 mm
IN FRONT OF THE APPLIANCE
500 mm
R C.H. return
22 mm Compression
M C.H. flow
22 mm Compression
G Gas connection
15 mm Compression
E D.H.W. inlet
15 mm Compression
U D.H.W. outlet
15 mm Compression
S3 Condensation outlet ø 20
S Safety valve discharge