BE SURE TO FOLLOW SAFETY RULES AND INSTRUCTIONS
MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE CHART BELOW.
FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT IQ POWER TOOLS AT 1-(888)274-7744.
TROUBLE! SAW WILL NOT START
WHAT’S WRONG?
WHAT TO DO
1. Saw not plugged in
1. Plug in saw
2. Saw will not run (plugged in; switch on)
2. Push switch to off and push the reset button on the GFCI
3. Fuse blown or circuit breaker tripped
3. Push switch to off and replace fuse or reset
circuit breaker.
4. Cord damaged
4. Have cord replaced by authorized service center.
5. Brushes worn out 5. Replace brushes.
TROUBLE! SAW MAKES UNSATISFACTORY CUTS
WHAT’S WRONG?
WHAT TO DO
1. Dull cutting blade
1. Use dressing stone
2. Blade not cutting
2. Check your power source or try a different blade
3. Build up on cutting blade 3. Use dressing stone to remove build up
4. Incorrect cutting blade for work being done
4. Change the blade
TROUBLE! CUTTING WHEEL DOES NOT COME UP TO SPEED
WHAT’S WRONG?
WHAT TO DO
1. Extension cord too small of a wire gauge or too long
1. Replace with adequate size cord
2. Arbor loose
2. Tighten arbor
3. Low house voltage
3. Contact your electric company
TROUBLE! MACHINE VIBRATES EXCESSIVELY
WHAT’S WRONG?
WHAT TO DO
1. Saw not mounted securely to stand 1. Reposition stand.
2. Stand or bench on uneven floor
2. Reposition on flat level surface
3. Damaged saw blade
3. Replace blade
TROUBLE! DOES NOT MAKE ACCURATE CUTS
WHAT’S WRONG?
WHAT TO DO
1. Cutting guide not secure to fence 1. Check and adjust
2. Blade is not square to fence 2. Check and adjust
3. Blade is not perpendicular to table surface
3. Check and adjust fence
4. Work piece moving
4. Use edge guide.
TROUBLE! LOSS OF VACUUM SUCTION
WHAT’S WRONG?
WHAT TO DO
1. Vacuum motor not running
1. Check vacuum and motor plug
2. Filter plugged
2. Spin filter cleaning knob
3. Dust tray in unlocked position
3. Lock dust tray in up position
4. Dust tray over filled with dust
4. Empty dust tray and remove dust build up around
filter and cyclones.
TROUBLESHOOTING GUIDE