If the detection area is too small for your requirements, try angling the sensor head up.
Angling the head downwards will reduce the detection area should a smaller range be required.
The TIME setting controls how long the unit remains illuminated following activation and after all
motion ceases. It is controlled by the slide switch shown on Diagram C and can be set to 1, 5 or
12 minutes.
Adjust the sensitivity (SENS) control to increase/decrease the detection range as desired. Turn
CLOCKWISE to increase the sensitivity, ANTI-CLOCKWISE to decrease.
During Day time, the LEDs will scroll from left to right, indicating the unit is in
Automatic Mode
and on detection of movement the LEDs will flash on and off quickly to indicate a signal has been
sent to the receiver.
During Night time, the LEDs will scroll from left to right indicating that the unit is in
Automatic
Mode
and on detection of movement the LEDs will turn OFF, and turn the Halogen lamp ON to
indicate a signal has been sent to the receiver.
MASKING THE SENSOR LENS
To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using the masking tape provided in the accessory pack (see diagram D). For your information,
the top section of the lens covers long range detection, the bottom covers short range. Similarly
the left and right lens sections cover the left and right detection areas respectively.
MANUAL OVERRIDE MODE - SINGLE LED ILLUMINATED
The light can be switched on for longer time periods at night by use of the
Manual Override
Mode
. This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker once (off/on) within 2 seconds. The unit will now
illuminate continuously until it is switched back into
Automatic Mode
.
SF-PTV180-500-T.qxd 13/04/2005 13:51 Page 6