WALK TESTING PROCEDURE

The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in
the desired direction.

Set the two adjustment controls on the underside of the unit (diagram C) to the following
positions:                         

TIME - Fully anti-clockwise
DUSK - Fully clockwise

The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 5
seconds each time. This allows testing to be carried out to establish the best position for the
sensor.

Switch on the mains power.  The lamp will immediately illuminate as the unit goes through its 
"warm-up" period. After approximately 1 - 2 minutes the lamp will extinguish. Try to remain
outside the detection area during the warm-up period. Walk across the detection area approx 5
metres from the unit. As you cross a detection "zone" the lamp will illuminate. Now stand still until
the lamp extinguishes (this should take approx. 5 seconds).
Start moving again. As you cross each "zone" the lamp will illuminate.
Repeat the above, walking at various distances and angles to the unit. This will help you to
establish the detection pattern.

If the detection area is too small for your requirements, try angling the sensor head up. This will
increase the coverage distance.  Angling the head downwards will reduce the range should a
smaller coverage area be required. 

SETTING UP FOR AUTOMATIC OPERATION.

When walk tests are complete, the unit can be switched to automatic operation :

The TIME setting controls how long the unit remains illuminated following activation & after all
motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the
maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting.
The DUSK control determines the level of darkness required for the unit to start operating. The
setting is best achieved by the procedure below:

Set the DUSK control knob fully anti-clockwise

. The unit will now start operating at dusk. 

If you require the light to activate earlier, wait until the ambient light level reaches the level of
darkness at which you wish the lamp to become operative, SLOWLY rotate the control in a
clockwise direction until a point is reached where the lamp illuminates. Leave the control set at
this point.

Fix the mounting plate to the wall.  Take care not to overtighten the screws to prevent damage to
the mounting plate.  If using a power screwdriver, use the lowest torque setting.

SF-ATS-PAR38S-B.qxd  16/05/2005  11:23  Page 6

Содержание E-680

Страница 1: ...ndbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 I N S T A L L E R G U I D E Security Twinspot E 680 V1 0 04 05 IQ ATS 140 240 B SF ATS PAR38S B qxd 16 05 2005 11 23 Page 1 ...

Страница 2: ...sitive Restrict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m Time TOP VIEW SIDE VIEW 2 5m A 140º Dusk SF ATS PAR38S B qxd 16 05 2005 11 23 Page 2 ...

Страница 3: ...nvironmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and does not cover any claims...

Страница 4: ...ar side effects If in any doubt consult a qualified tradesperson or electrician SECTION ONE The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful position...

Страница 5: ...use or switching off the circuit breaker before proceeding with the installation CONNECTION This product can be wired in one of two ways Method 1 The unit comes pre wired with approximately 1 metre of cable Connect as follows o Drill a hole through the wall at the mounting position o Pass the pre wired cable through the hole o Connect this cable into the household mains supply using an internal ju...

Страница 6: ... the detection area is too small for your requirements try angling the sensor head up This will increase the coverage distance Angling the head downwards will reduce the range should a smaller coverage area be required SETTING UP FOR AUTOMATIC OPERATION When walk tests are complete the unit can be switched to automatic operation The TIME setting controls how long the unit remains illuminated follo...

Страница 7: ... dusk adjust the control slightly clockwise Continue to adjust until the unit operates as desired MASKING THE SENSOR LENS To reduce the sensor coverage preventing detection in unwanted areas mask the sensor lens using electrician s tape or similar see diagram D For your information the top section of the lens covers long range detection the bottom covers short range Similarly the left and right le...

Страница 8: ... Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control...

Страница 9: ...nnoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the ...

Отзывы: