background image

IQ Europe Limited 

Sandbeck Lane, Wetherby LS22 7TW.

Visit us at www.iq-europe.co.uk 

Installation helpline 0871 717 1100

INST

ALLER

GUIDE

Security Twinspot

E-680

V1.0 - 04/05

IQ-ATS-140-240-B

SF-ATS-PAR38S-B.qxd  16/05/2005  11:23  Page 1

Содержание E-680

Страница 1: ...ndbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 I N S T A L L E R G U I D E Security Twinspot E 680 V1 0 04 05 IQ ATS 140 240 B SF ATS PAR38S B qxd 16 05 2005 11 23 Page 1 ...

Страница 2: ...sitive Restrict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m Time TOP VIEW SIDE VIEW 2 5m A 140º Dusk SF ATS PAR38S B qxd 16 05 2005 11 23 Page 2 ...

Страница 3: ...nvironmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and does not cover any claims...

Страница 4: ...ar side effects If in any doubt consult a qualified tradesperson or electrician SECTION ONE The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful position...

Страница 5: ...use or switching off the circuit breaker before proceeding with the installation CONNECTION This product can be wired in one of two ways Method 1 The unit comes pre wired with approximately 1 metre of cable Connect as follows o Drill a hole through the wall at the mounting position o Pass the pre wired cable through the hole o Connect this cable into the household mains supply using an internal ju...

Страница 6: ... the detection area is too small for your requirements try angling the sensor head up This will increase the coverage distance Angling the head downwards will reduce the range should a smaller coverage area be required SETTING UP FOR AUTOMATIC OPERATION When walk tests are complete the unit can be switched to automatic operation The TIME setting controls how long the unit remains illuminated follo...

Страница 7: ... dusk adjust the control slightly clockwise Continue to adjust until the unit operates as desired MASKING THE SENSOR LENS To reduce the sensor coverage preventing detection in unwanted areas mask the sensor lens using electrician s tape or similar see diagram D For your information the top section of the lens covers long range detection the bottom covers short range Similarly the left and right le...

Страница 8: ... Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control...

Страница 9: ...nnoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the ...

Отзывы: