Walk across the detection area approx 5 metres from the unit. As you cross a detection "zone"
the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5
seconds).

Start moving again. As you cross each "zone" the lamp will illuminate.

Repeat the above, walking at various distances and angles to the unit. This will help you to
establish the detection pattern.

If the detection area is too small for your requirements, try angling the sensor head up. This will
increase the coverage distance.  Angling the head downwards will reduce the range should a
smaller coverage area be required. 

SETTING UP FOR AUTOMATIC OPERATION.

When walk tests are complete, the unit can be switched to automatic operation :

The TIME

setting controls how long the unit remains illuminated following activation & after all

motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the
maximum time (fully clockwise) is approx. 12 minutes. Set the control to the desired setting
between these limits.

The DIMMER

control determines the brightness of the lamp in the dimmed mode.  Set the control

between minimum (fully anti-clockwise, 10% light output) and maximum (fully clockwise, 60%
output) at the desired level.

The DUSK

control determines the level of darkness required for the unit to start operating. The

setting is best achieved by the procedure below:

Set the DUSK control knob fully anti-clockwise

. The unit will now start operating at dusk. 

If you require the light to activate earlier, wait until the ambient light level reaches the level of
darkness at which you wish the lamp to become operative, SLOWLY rotate the control in a
clockwise direction until a point is reached where the lamp illuminates. Leave the control set at
this point.
At this position, the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie.
when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late
(ie. dusk), adjust the control slightly clockwise. 
Continue to adjust until the unit operates as desired.

MANUAL OVERRIDE MODE
At night

, to switch the unit into manual override mode, turn the power off/on within 1

second,using the internal wall switch/circuit breaker. The unit should now enter manual override
mode until dawn when it will reset to its normal operation. The lamp will illuminate at full power
until dawn.

To reset back to Auto mode, turn off the power again and wait 20 seconds. Switch back on. The
unit will go through its warm-up cycle before resuming normal PIR operation.

MASKING THE SENSOR LENS

To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using electrician’s tape or similar (see diagram D).  For your information, the top section of the
lens covers long range detection, the bottom covers short range.  Similarly, the left and right lens
sections cover the left and right detection areas respectively.  

SF-73CA180-150-D.qxd  16/05/2005  11:20  Page 8

Содержание E-614

Страница 1: ...4 05 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 IQ 73CA180 150 D IQ 73CA180 300 D Security Floodlight E 614 E 616 SF 73CA180 150 D qxd 16 05 2005 11 20 Page 1 ...

Страница 2: ...ification ON CONDITION THAT The buyer takes advantage of any return to store scheme operated by the seller from whom it is bought If the product has a defect outside the period of any seller s return to store scheme it should be returned to IQ Europe Limited at Sandbeck Lane Wetherby W Yorks LS22 7TW England at the expense of the buyer together with evidence of the date of purchase it is the respo...

Страница 3: ...rom nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is ...

Страница 4: ...is located onto the wall plate by two lugs which are inserted into the rectangular slots in the top of the wallplate To remove loosen but do not remove the fixing screw and lift the body of the floodlight upwards to release from the wall plate diagram F Mark the position of the fixing holes Ensure wall plate is correctly positioned Note the orientation of the wall plate diagram E Drill the holes I...

Страница 5: ...strict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m Time TOP VIEW SIDE VIEW 2 5m A 180º Dusk Dimmer Adjustment SF 73CA180 150 D qxd 16 05 2005 11 20 Page 5 ...

Страница 6: ...E G UP F H wall plate fixing screw SF 73CA180 150 D qxd 16 05 2005 11 20 Page 6 ...

Страница 7: ...h the best position for the sensor Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After approximately 1 2 minutes the lamp will extinguish Try to remain outside the detection area during the warm up period CONNECTION Connect the cable to the terminal block on the unit as follows see connection diagram NEUTRAL Blue N EARTH Green Yellow LIV...

Страница 8: ...ll now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates Leave the control set at this point At this position the unit should become operative at approximately the sa...

Страница 9: ...en 150W or 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unscrew cover screw on the top of the unit 4 Open the glass cover The cover is mounted on hinges and will swing open 5 To remove existing bulb depress then lift one end of the bulb to remove 6 Install new bulb by inserting one end first and depressing gently until enough clearance is gained to seat the other end in the soc...

Страница 10: ...nal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust t...

Страница 11: ...yance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the lig...

Отзывы: