SECTION SIX

TROUBLESHOOTING GUIDE

PROBLEM

o

Lamp stays ON all the time at

night.

o

PIR keeps activating for no 

reason / at random.

o

PIR sensor will not operate at

all.

o

The PIR sensor will not 

operate at night.

o

Unit activates during the 

daytime

o

PIR coverage is poor/sporadic

Detection range varies from

day to day

o

Lamp flashes on/off on/off in a

regular pattern

SOLUTION

The unit may be suffering from false activation. Cover the
sensor lens completely with a thick cloth. This will prevent the
sensor from "seeing" anything. If the unit now switches off
after the set time duration and does not re-activate, this
indicates that the problem was caused by false activation. The
problem may be solved by slightly adjusting the
direction/angle of the sensor head (see previous section).
You may not be allowing the unit time to complete it's 
warm-up period. Stand well out of the detection range and
wait (the warm-up period should never exceed 5 minutes).
Occasionally, winds may activate the sensor. Sometimes
passages between buildings etc. can cause a "wind tunnel"
effect.
Ensure the unit is not positioned so as to allow detection of
cars/people using public thoroughfares adjacent to your
property.

Check that the power is switched ON at the circuit
breaker/internal wall switch.
Turn OFF the power to the unit and check the wiring
connections as per the diagram (see previous section 3).
Ensure no connections are loose.
Check the lamp. If the lamp has failed, replace. Ensure that
the lamp is seated correctly in the lampholder.

The level of ambient light in the area may be too bright to
allow operation at the current DUSK setting. During the hours
of darkness, adjust the DUSK control slowly clockwise until
the lamp illuminates. Refer to previous section for more
details.

The level of ambient light in the area may be too dark for the
current DUSK setting. During daylight, adjust the DUSK
control slightly anti-clockwise. When the lamp extinguishes,
enter the detection area. If the PIR still activates, the setting is
still too high. Repeat the above procedure until the PIR does
not activate when you enter the detection area. Refer to
previous section for more details.

Unit may be poorly located. See previous section - ‘Selecting
The Location’ and re-locate the unit.
PIR sensors are influenced by climatic conditions. The colder
the ambient temperature, the more effective the sensor will
be. You may need to make seasonal adjustments to the
sensor head position to ensure trouble-free operation all year
round.
The PIR is sensing illumination from its own lamp, turning it off
as if it were daylight every time the lamp illuminates. Turn the
LUX setting clockwise until the flashing stops

SF-73CA180-150-D.qxd  16/05/2005  11:20  Page 10

Содержание E-614

Страница 1: ...4 05 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 IQ 73CA180 150 D IQ 73CA180 300 D Security Floodlight E 614 E 616 SF 73CA180 150 D qxd 16 05 2005 11 20 Page 1 ...

Страница 2: ...ification ON CONDITION THAT The buyer takes advantage of any return to store scheme operated by the seller from whom it is bought If the product has a defect outside the period of any seller s return to store scheme it should be returned to IQ Europe Limited at Sandbeck Lane Wetherby W Yorks LS22 7TW England at the expense of the buyer together with evidence of the date of purchase it is the respo...

Страница 3: ...rom nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is ...

Страница 4: ...is located onto the wall plate by two lugs which are inserted into the rectangular slots in the top of the wallplate To remove loosen but do not remove the fixing screw and lift the body of the floodlight upwards to release from the wall plate diagram F Mark the position of the fixing holes Ensure wall plate is correctly positioned Note the orientation of the wall plate diagram E Drill the holes I...

Страница 5: ...strict RHS detection Restrict LHS detection Restrict long detection Restrict short detection Lens Mask Less sensitive 12m Time TOP VIEW SIDE VIEW 2 5m A 180º Dusk Dimmer Adjustment SF 73CA180 150 D qxd 16 05 2005 11 20 Page 5 ...

Страница 6: ...E G UP F H wall plate fixing screw SF 73CA180 150 D qxd 16 05 2005 11 20 Page 6 ...

Страница 7: ...h the best position for the sensor Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After approximately 1 2 minutes the lamp will extinguish Try to remain outside the detection area during the warm up period CONNECTION Connect the cable to the terminal block on the unit as follows see connection diagram NEUTRAL Blue N EARTH Green Yellow LIV...

Страница 8: ...ll now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates Leave the control set at this point At this position the unit should become operative at approximately the sa...

Страница 9: ...en 150W or 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unscrew cover screw on the top of the unit 4 Open the glass cover The cover is mounted on hinges and will swing open 5 To remove existing bulb depress then lift one end of the bulb to remove 6 Install new bulb by inserting one end first and depressing gently until enough clearance is gained to seat the other end in the soc...

Страница 10: ...nal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust t...

Страница 11: ...yance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the lig...

Отзывы: