1 OF 2
IG071717-2.0
FENCER
®
FOIL
™
2
INSTALLATION GUIDE
®
INSTALLATION GUIDE
FENCER
®
FOIL
™
2
PREMIUM DIFFUSION
LED FIXTURE
DRY LOCATION
90+
HIGH CRI
DIMMABLE
120VAC
INCLUDED MODELS / QUICK SPECS
Input Voltage
~120VAC / 50 ~ 60Hz
Maximum Series Run
300W
Ambient Temperature
-4° ~ 122°F (-20° ~ 50°C)
Environment
Indoor / Dry Locations
INSTALLATION - UL LISTED 1598 HARD-WIRED LUMINAIRE
SKU
Power Consumption
DI-120V-FOIL-PDxx-12-yy
7W
DI-120V-FOIL-PDxx-18-yy
10W
DI-120V-FOIL-PDxx-24-yy
13W
DI-120V-FOIL-PDxx-32-yy
17W
xx - Indicates CCT (Kelvin); yy - Indicates color finish
1.
Install in accordance with local and national electrical codes.
2.
This product is intended to be installed and serviced by a licensed
electrician.
3.
Turn power off at circuit breaker prior to installation or servicing.
4.
Risk of Electric Shock! Do not use any connection pin to touch
electrical connections.
5.
For indoor use only. Do not install outdoors or in potentially combustive
environments.
6.
Do not exceed 300W for daisy-chain series connections.
7.
Do not install this product in an environment outside the listed
ambient temperature.
8.
Do not modify or disassemble this product beyond instructions or the
warranty will be void.
9.
See the ‘FENCER SERIES Dimmer Compatibility List’ for a list of
compatible dimming controls.
DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER!
Read all warnings and installation instructions thoroughly.
WARNING
WARNING!
TURN MAIN POWER OFF BEFORE INSTALLING OR SERVICING!
Read all warnings and installation instructions thoroughly.
SAFETY & WARNINGS
Romex (NM) or BX Cable
Remove cover port of FENCER FOIL Direct Wire Switch & J-Box (DI-FOIL-
JBOX-**)
to access wiring compartment. Included push-in wire connectors
should only be used with 12AWG wire. If using thinner gauge wire cut off
pre-attached connectors and make connection with standard UL Listed
twisted wire connectors.
Line (HOT)
Neutral
Ground
Black
White
Green/Yellow
WIRING KEY
Push-in wire connectors
Use FENCER FOIL Extension Cable (DI-FOIL-**EXT-**) to connect
to FENCER FOIL Direct Wire Switch & J-Box (DI-FOIL-JBOX-**) or
link between FENCER FOIL fixtures.
3/8” Romex Connector
Use FENCER FOIL 72 in. Power Cable
with Hard-Wire Connection (DI-FOIL-
HWPWR-**) to connect to FENCER FOIL
Direct Wire Switch & J-Box (DI-FOIL-
JBOX-**). Hard-wired connections must be
made in the FENCER J-box or other Listed
enclosure.
Use FENCER FOIL Linkable End-to-End Connector, one included,
(DI-FOIL-ETE-**) to link FENCER FOIL fixtures together.
Ensure all terminal covers are
attached to open ports once
installation is complete!
T
erminal
Cover
T
erminal
Cover Screw