2 OF 2
®
Toll Free: 877.817.6028 | Fax: 415.592.1596 | www.DiodeLED.com | [email protected]
© 2017 Elemental LED, Inc. All rights reserved. Specifications are subject to change without notice.
IG071717-2.0
FENCER
®
FOIL
™
2
INSTALLATION GUIDE
INSTALLATION - UL LISTED 153 PORTABLE LUMINAIRE
Use FENCER FOIL 72 in. Power Cable with
AC Plug (DI-FOIL-ACPWR-**)
to connect to
electrical receptacle.
Use FENCER FOIL Linkable End-to-End Connector, one included,
(DI-FOIL-ETE-**) to link FENCER FOIL fixtures together.
Use FENCER FOIL Extension Cable
(DI-FOIL-**EXT-**) to link FENCER
FOIL fixtures together.
MOUNTING
Draw a guiding line before securing
mounting brackets to surface.
Mounting Brackets (included)
Use included Allen
key to loosen or
tighten set screw.
Secure mounting brackets to surface with screwdriver. To adjust
pivot angle, adjust tightess with screwdriver and finish tightening
with allen key and set screw.
NOTE: Mounting Brackets only pivot in one
direction. See image below.
FENCER FOIL 72 in. Power Cable
with AC Plug (DI-FOIL-ACPWR-**)
connects to electrical receptacle.
FENCER FOIL 72 in. Power Cable with Hard-
Wired Connection (DI-FOIL-HWPWR-**) must
be wired to FENCER FOIL Direct Wire Switch
& J-Box (DI-FOIL-JBOX-**) or other Listed
enclosure.