17
All of the GND terminals on the board may be used for the “ – “ power terminal or for a common contact.
The 6 terminals at the top right corner of the terminal board are for the termination of ground loops. These
terminals correspond with the 3 available plug-in loop detector slots. The loop detector slots are available for
use as an EXIT, SAFE and AUX configuration.
•
The EXIT detector will provide an open contact to the controller and will display “Exit Loop/Term”.
•
The SAFE detector will provide a “safe” or close-reversing contact to the controller and will display “Safe
Loop/Term”.
•
The AUX detector will provide the output contacts from the detector to the terminals on the board labeled
“A – AUX – B”. When an AUX loop is utilized and detecting, the output from the detector will be able to
be utilized from the Aux A and B terminals and from here you can jump to whatever contact you would
like. For example, if you should require a shadow loop, insert the shadow loop wires into the AUX loop
terminals at the top right corner of the board and then use a jumper wire and insert it between the “Aux
A” and “Shadow” terminals.
Be sure to disconnect and disable any magnetic or other gate locks before learning an operator
Programming the IQ Control Board
The following is a list of programming and available features. Please be aware that the IQ control board is one
of the most advanced gate operator circuit boards available and take care when programming and choosing
desired features. Refer to this manual if a feature that you desire is needed or if any changes are necessary to
be made in the menus.
The IQ control board is divided into 7 menus. Using the round rotating programming knob on the
display board, you can scroll through the menus and select an option or enter a menu by depressing the
programming knob. When changes are being made in any menus the programming “
*
“ will be displayed at the
top left of the screen. The 7 menus consist of the following:
Adjust the Clock
Adjust Time Settings
Auxiliary Settings
Maintenance Menu
Motor Drive Menu
IQ Gate Learning
Error and Fault Log
To enter any of the menus, rotate the programming knob one click to the right, or clockwise. The first option
that will appear is “Enter Password / None”. This is indicating that the menu is not being password protected. If
the password feature was/is being utilized then the appropriate password would need to be entered prior to
advancing into the menus past this point. After 1 second, the “Enter Password / None” display will expire and
“Adjust the Clock” will be displayed. At this point, you have entered the menu and may scroll clockwise or
counter-clockwise to make the adjustments that you desire. To enter a menu, scroll until the one you desired is
displayed and push the programming knob to enter. To exit a sub-menu, scroll all the way clockwise until “exit
the sub-menu” is displayed and then push the programming knob in. To exit the main menus, just scroll all the
way counter-clockwise until the time and date is displayed.