{Some possible and popular uses for the security timer are as follows: a “Free Entrance” loop by day and a
“Safety” loop by night; the automatic disabling of the free exit loop after work hours; a controlled output from the
auxiliary relays utilizing the Aux In terminals; etc.}
Auxiliary Settings / Enter to View/Adjust
•
Aux Input Terminals
(These are available programmable inputs that can be programmed to take on the function that is selected
when the AUX terminal is activated)
o
Open
o
Safe
o
Shadow
o
Fire
o
Close
o
Photo Eye Close (stops the gate from closing but doesn’t reverse the gate)
o
Aux Out 1 (momentary activation of Aux 1 output relay)
o
Aux Out 2 (momentary activation of Aux 2 output relay)
o
Toggle Aux 1 (toggles Aux 1 output relay on/off)
o
Toggle Aux 2 (toggles Aux 2 output relay on/off)
o
7-day Open Timer Off (turns off the 7-day open timer until the next open schedule)
o
Hold Open (momentary contact will hold open gate and release it)
•
Aux 1 Output Relay
•
Aux 2 Output Relay
(These are available options for the Aux 1/2 output relays to perform if selected)
o
Pulse on Open Limit (a 2 second relay activation on the open limit)
o
Pulse on Close Limit (a 2 second relay activation on the close limit)
o
Hold on Open Limit (latches the relay on the open limit)
o
Hold on Close Limit (latches the relay on the close limit)
o
Pulse on Motor Open (a 2 second relay activation when gate is opening)
o
Pulse on Motor Close (a 2 second relay activation when gate is closing)
o
Hold on Motor Open (latches the relay when gate is opening)
o
Hold on Motor Close (latches the relay when gate is closing)
o
Hold on UL-325 Alarm (latches the relay upon a UL-325 alarm)
o
Aux Input Received (activates the relay when the Aux input is in use)
o
AC Power Loss (activates the relay upon AC power loss detection which is measured when the
gate receives less than 23.5 VDC)
o
Low DC Power (activate the relay upon low DC power detection, a value of equal to or less than
75% of full power supplied)
o
Thermostat Engaged (activates the relay when the thermostat is engaged)
o
Maintenance Request (activates the relay upon a maintenance request)
o
Hold on Motor Run (activates the relay whenever the gate is running)
•
Recycle Test Mode = OFF, ON (This is for testing purposes. If selected, it will cause the gate to cycle
open and close unless stopped with the radio input or turned off in this menu)
Aux Input Terminal 1