Operation
page
18
9.3.1
Configuration
Home
Configuration
Home
Configuration
Parameter
In the configuration settings the the unit system can be selected
and the required parameters entered, this to calculate the
leakage costs per year.
Selection of ISO or US unit system
Enter cost per 1000 volume units &
Enter currency
Default: 2 € / 1 m³
Enter working hours per year
Sensor type
Selection of the sensor type according to the application and
ambient conditions, see therefor chapter 6.
Pressure (line pressure in bar)
Distance (distance to leakage in m)
Depending on the selected sensor type, there are up to 4 pre-
defined pressure and distance values that can be selected
directly as well as two fields (white) in which values for the
pressure and the distance are freely selected..
The
pressure
can be set variably between 1 - 10 bar.
For the
different sensor types
different
minimum and
maximum distances
from the
leakage detector
to the
leakage are defined to calculate valid leakage loss and costs
per year. These distances must be strictly adhered to.