Hardware
2.70.2.2 Net Transfer
Description
A station user can transfer any kind of CO line to a station in other systems by pressing
[TRANS]
button and dialing a transferred station such as a call transfer within the same system.
There are two kinds of transfer, screened and unscreened transfer.
Engineering notice)
There are two kinds of standard transfer method in QSIG and H.450; Transfer by join and
Transfer by rerouting. The main difference is how control the connecting path between
transferring and transferred station. In case of Transfer by join, additional connecting path will
be needed to transfer the call to another station. In case of Transfer by rerouting, new
connecting path is used to transfer the call and old connecting path of transferring station will
be cleared.
Operation
Screened transfer
1. Press the
[TRANS]
button at a station during conversation with a CO line. The CO
line is placed on Exclusive Hold.
2. Dial the station number of another system to transfer the call. The transferred
station of another system receives a ring signal.
3. Announce when the transferred station answers. Both stations can make a
conversation each other, but the held CO is still in waiting on Transfer hold.
4. Hang-up to complete the transfer.
Unscreened transfer
1. Press the
[TRANS]
button at a station during conversation with a CO line. The CO
line is placed on Exclusive Hold.
2. Dial the station number of another system to transfer the call.
3. Hang-up to complete the transfer.
Conditions
1. If both of transferred and transferred-to stations are located in the same system, the
networking path will be cleared. That is, the transfer call will be setup as intercom
call.
2. The transfer will be canceled when user presses the flashing [CO] or
[TRANS]
button.
3. Net Transfer call does not recall to the origination.
4. User hears an error tone if there is no idle networking path.
5. Net transfer is not activated to a busy station.
Содержание iPECS-LIK
Страница 106: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 93 Related Features Hardware iPECS Phone ...
Страница 138: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 125 Hardware VOIM8 or VOIM24 ...
Страница 150: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 137 Hardware VSF and or VMIM ...
Страница 175: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 162 Related Features Hardware ...
Страница 257: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 244 2 81 ...
Страница 326: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 313 1 CLI is 01234567890123456 ...
Страница 350: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 337 Hardware iPECS Phone ...
Страница 361: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 348 Hardware iPECS Phone ...
Страница 370: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 357 Hardware iPECS Phone w Display ...
Страница 424: ...iPECS LIK Feature Description Operation Manual Issue 6 0d1 411 Hardware ...